My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2400 33RD ST CONTRACT AGREEMENT 2016-01-01 MF Import
>
Address Records
>
33RD ST
>
2400
>
CONTRACT AGREEMENT
>
2400 33RD ST CONTRACT AGREEMENT 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2017 3:28:48 PM
Creation date
4/1/2017 3:32:27 PM
Metadata
Fields
Template:
Address Document
Street Name
33RD ST
Street Number
2400
Tenant Name
CONTRACT AGREEMENT
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
382
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTACHMENT A TO SECTION 01900 <br />REVISIONS TO THE STANDARD PLANS AND SPECIFICATIONS <br />pipe and on ihe ground in each instance shall be that shown or directed by the Resident <br />Engineer. The blocking shall, unless otherwise shown or directed, be so placed that ihe pipe <br />and fitting joints, including nuts and boNs, will be accessible ior repair. <br />Mechanical Joint Restraining Devices <br />Mechanical Joint Restraining Devices may be used to restrain joints and fittings in lieu ot <br />concrete blocking where approved by the Resident Engineer. Mechanical Joint Festraining <br />Devices shall cr�nform to Section 9-30.2(6) oi ihe Standard Speci(ications and ihese Special <br />Provisiona. Joint restraint shail be installed per the manufacturer's recommendations. <br />When mechanical joint resira�ning devices are used at bends, mechanical joint restraining <br />devices shall also be used o�, all pipe fittings within 20 foet on either side of bends unless <br />otherwise approved by the R�sident E.igineer. <br />Res�rained joinis shall be provided where indicated on ihe Plans, or as directed ` y the Resident <br />Engineer. <br />Hydrostatic Pressure Test <br />Section 7-09.3(23) is supplemented with ihe following: <br />It shall be the Contractor's responsibility to provide an approved doubie-check assembly for the <br />purpose of testing and flushing. There will be no charr7e for the water used in this operation. <br />Flushing <br />Section 7-09.3(24)A is supplemented with the (ollowing: <br />Disinfection by the Dry Calcium Hypochlorite Method shatl not 5e ailowed. <br />Di�in(ection of water mains shall be pertormed in accordance with A4VWA Standard C651-86 <br />and Section 7-09.3(24) o( the Standard Specitications. <br />Flushing water must be disposed of in accordance with City of Everett and Washington Stata <br />Department of Ecology Standards. Flushing water may require dechlorination or disposal to <br />City of Everel� sewer system. Method of disposal shall be approved by the Resident Fngineer. <br />VALVES FOR WATER MAINS <br />Materials <br />The (irst p�ragraph of Section 7-12.2 is supplemented with ihe tollowing: <br />Materials shall meet the requirements of ihe following sections o( these Special Provisions: <br />Valve Stem Extensions <br />Consiruction Requirements <br />Section 7-12.3 is supplemented with ihe following: <br />9-30.3(6) <br />Valve and Valve Box Installation: The valve and valve box shall be set plumb with the vaive box <br />centered on ihe operator nut. Valve boxes shall be set fiush in pavement and gravel roads. When <br />ihe top of the valve operating nut is more than 2 feet below (inished grade, a valve operaiing <br />extension shall be ir.stalled per City of Everett Standard Drawing 504. The minimum extension <br />lengih sliall be 12 inches. <br />Tapping Sleeve and Valve: All taps to existing water mains shall be wet taps and shall be done by <br />City of Everett personnel. Contractor shall provide all materials and parts to perform all pavement <br />sawing, pavement removal, excavations, shoring, and traffic conirol and other work required to <br />Capital Projects Commuter Rail Attachment A to Section 01900 - 22 IFB No. RTA/CP 21-06 <br />�[verett Station Phase 2REVISIONS TO THE STANDARD PLANS AND SPECIFICATIONSAddendum No.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.