My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2400 33RD ST CONTRACT AGREEMENT 2016-01-01 MF Import
>
Address Records
>
33RD ST
>
2400
>
CONTRACT AGREEMENT
>
2400 33RD ST CONTRACT AGREEMENT 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2017 3:28:48 PM
Creation date
4/1/2017 3:32:27 PM
Metadata
Fields
Template:
Address Document
Street Name
33RD ST
Street Number
2400
Tenant Name
CONTRACT AGREEMENT
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
382
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTACHMENT A TO SECTION 01900 <br />REVISIONS TO THE STANDARD PLANS AMD SPECIFICATIONS <br />Saddles <br />For 3/4" and 1" services use Romac, Ford, or Mueller service saddles with iron pipe th�ead. <br />For 7" services use Romac, Ford, or Mueller double strap service saddles with iron pipe ihread. <br />Corporation Stops <br />For 3/4" and 1" services use Ford F600 cc, 700 IP corporation stops, or approved equal. <br />For 2' services use 2" brass nipples and super heavy-duty 2" gai2 �alves with resilient seat and 2" <br />operaling nut. Two-inch gate valves shali be Waterous Series 500, �1&H #d06; , or approved equal. <br />Two-inch gate valves snall be installerl with two piece adjustable valve boxes and extensions as <br />described in Section 930.3(4) of these Special Provisions. <br />Service Pipes <br />For 3/4", 1", and 2" service lines, tubing shall be either polyethylene or copper tubing. <br />Copper Tubing <br />Copper tubing shall be annealed, seamless, and con(orm to the requirements o( ASTM B 88M, Type <br />K. <br />Polyethylene Tubing <br />Polye�hylene tubing shall: <br />1. Meet the requirements o( AWWA C901. <br />2. Be high moleailar mass with at least 200 PSI rating. <br />3. Have a#10 copper irace wire wrapped along its enlire lengih (one wrar per foot). <br />3/4" and 1" polyethylene lubing shall be iron pipa size (IPS)-ID ASTM D2239-SSIDR7 <br />(PE3408). <br />2" polyethylene shall be 2" cepper size� (CTS)-nD ASTM D2737-SDR9 �PE3408). <br />Service Fittings <br />For 3/4" and 1" service titlings, use Ford seties LAO (1/8 bend) ar LO (1/4 bend) titling for flare x <br />flare copper or pack joint compression fittin;�, er approved equal. Use of pack joinUccrc�pression <br />filting on polyethylene pipe requires approoriate stainless steei stiflener. Physical bends in <br />polyethylene pipe are not allowed, use approprate 1/4 or 1/8 bends as specified above. <br />For 2" service tittings, use Ford C28-77 or C84-77 •+vith appropriate stainless sieel insert stitiener, or <br />approved equal. Physical bends in polyethylene p:pe 3re not allowed, use brass elbows. <br />Meter Setters <br />3/4" meter setlers shall be A.Y. McDonald 62-212 WWDD33-15, or approved equal. <br />1" meter setters shall be A.Y. McDonald 62-415 WWDD44-15, or approved equal. <br />2" meter setters shall be ford 90 series copper setter aVBH87-12B-11-77 with vertical i�iei and <br />outlet, or approved equal. <br />Rronze Nipples and Fittings <br />Bronz2 threaded nipples and fittings shall meet the requiremenis of ANSI B-15.iS, ASA 125 pound <br />class. <br />Meter Boxes <br />Unless otherwise approved by tlie Resident Engineer, meter boxes located in rwn-lr3ffic areas shall <br />be constructed of high density polyethylene, and meter b�xes Incated in traffic areas, including <br />sidewslks, and pavement, shall be constructPd of reinforced concrete and be traffic bearing. <br />Capitai Projzcis Commuter Rail Attachment A to Section 01900 - 35 IFB No. RTA/CP 21-06 <br />� Everett Station Phase 2REVISIONS TO THE STANDARD PLANfi AND SPECIFICATiONSAddendum No.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.