tests, witnessed by a Fire Department inspector, shall be perfonned, along with a certificate of <br /> comp'�tion, prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Standard 72. Inst,;;lation of fire alarm <br /> components, including basic wiring, may not commei�ce before plans are approved by the Fire <br /> Department Plan Reviewer. Fire alarm drawings must be professionally �endered, in sufficient <br /> detail, and must be internally consistent. Ris2r diagrams must match instailation plans and load <br /> calculations. Components must be listed and approved for use together. Changes to plans must <br /> include new drawings and calculations and must be approved by the Fire Department Plan Reviewer <br /> prior to installation. Fire alarm installation is subject to field inspection by a Fire Department <br /> Inspector. An approved set of plans and the Building Department electrical permit must be present <br /> for any insiallation inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Building Department. <br /> Electrical inspections and approval are required prior to calling for acceptance tests. Call (425) 257- <br /> 881 G for permit information. <br /> 27. Commercial Cooking Cperations -A ventilating hood and duct system with an approved automatic <br /> fire-exlinguishing system shail be provided in accordance with the Mechanical Code for commercial- <br /> type food heat-processing equipmenl that produces grease-laden vapors. <br /> 28. Kitcfiens - Install a K-type fire extinguisher within 30 feet of the grill and deep fryers. <br /> 29. Phase 2 Onlv- Fire Suppression (Sprinkler) Svstem-An apprved automatic suppression system <br /> shall be provided as required by City Ordinance No. 1902-92, Chapter 16.76, of the Everett <br /> Municipal Code. The system must include a mechanical water gong bell. <br /> Plans for any such system shall be submitted to the Building Department for examination and <br /> approval. Such plans shall include plans for lhe underground mains ihat will supply the sprinkler <br /> _ system. <br /> The type of sprinkier to be installed will be determined by the Building O�cial. It may be an NFPA <br /> 13, �dFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler installation shall not <br /> begin without an approved and stamped set of plans from the Building Department. The Fire <br /> Department will also review the plans and shall field inspect the installa�ion based only on approved <br /> plans that must be on site. Changes to plans must be approved by both the Building and Fire <br /> Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 <br /> for private fire mains. Below-qround pipinq must be installed bv Washinqton State Patrol <br /> Licensed Underqround Sprinicler line certified "U" installers. For further information, contact <br /> the State Fire Marshal's Office at (360) 570-3134 or contact the Everett Fire Deaartm�nt at <br /> j425) 257-8123. All such tests shall be witnessed by a Fire Department inspector. Call (47.5) 257- <br /> 8123 to make an appointment for inspection. <br /> Contractors' materials and test certificates shall be submitted to the Everett Fire Department prior to <br /> issuance of any Certificates of Occupancy. <br /> Call (425) 257-8123 for more informatien. <br /> / <br /> � <br />