My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11419 19TH AVE SE XIAN DUMPLING AND NOODLE 2018-01-01 MF Import
>
Address Records
>
19TH AVE SE
>
11419
>
XIAN DUMPLING AND NOODLE
>
11419 19TH AVE SE XIAN DUMPLING AND NOODLE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2018 9:23:31 AM
Creation date
4/2/2017 1:25:21 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
11419
Tenant Name
XIAN DUMPLING AND NOODLE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, , <br /> 3. Please indicate a posted occupancy sign on the drawings for assembly use, per IBC table <br /> 1004.1.1, and IBC sediori 10043. <br /> Construction <br /> 1. New ceilings should be shown on the drawings to comply with the seismic installation details of <br /> NW Ceiling institute, attached. <br /> 2. The wall construction behind and adjacent to the hood should be shown on the drawings to <br /> indicate combustible or non-combustible construction, including the required dimensioned <br /> clearances, per IMC 506.3.6. <br /> 3. The listed assembly for the grease duct endosure system of one hour resistant grease duct fire <br /> wrap should be shown to meet the requirements of ASTM E 2336, raith the required clearances <br /> shown on the drawings, per IMC section 506.3.6, exception 3. <br /> 4. The start and termination of the grease duct fire wrap for the Type I hood ducts should be I, <br /> shown on building sections to extend from the Type I hoods to the outlet terminal, per IMC I <br /> Sedion 506.3.10.2. I <br /> 5. The kitchen ceiling height should be shown on the shown on the building sedions. Where the I <br /> kitchen ceiiing abuts the Type I hood, 18 inches of a smooth, cleanable, nonabsorbent and <br /> noncombustible material should be shown on the drawings between the hood and the ceiliny <br /> material, per the exception to IMC section 507.9. <br /> 6. An elevation should be shown on the drawings where the Type I hood abuks the wall. A <br /> smooth, cleanable, nonabsorbent and noncombustible material should be shown on the <br /> drawings and noted to extend 18 inches in all directions from the hood to the full height of the <br /> hood canopy, and to the base of the floor, per the exception to IMC section 507.9. <br /> 7. Elevations of all new toilet rooms should be targeted on the drawings. A side elevation of the <br /> toilet is also required to show Floor, base and wall treatments, per I8C section 1210. <br /> 8. i�ew doors and existing door sizes and hard�vare should be shown on a schedule Lo comply with <br /> minimum sizes, per IBC sections 1008.1.1 and 1008.1.9.1. <br /> 9. Toilet room exhaust fans cfm sho�dd be shown on new toilet rooms, per IMC table 403.3. <br /> 10.The relocated mop sink should bc positioned so that the clear door width into the kitchen is not <br /> reduced, per IBC 1005.1. <br /> 11.Walls, door locations, and door openings should be dimensione� so lhat someone could build <br /> them from the submitted drawings without having to ask someone else for information. <br /> 12. Electrical panels should not be located in toilet rooms, per NEC section 2370 A (2). Please <br /> darify the new location of the electrical panel for A103. <br /> Accessibility <br /> 1. Accessibility requirements in the drawings submitted for permit will be reviewed for compliance <br /> with adopted state laws. Federal ADA regulations and standards may be more restrictive. The <br /> Americans wilh Disabilities Act is enforced by the Department of Justice. <br /> �3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.