Laserfiche WebLink
� � _ <br /> Ltr. D. Jcnkins (80610-032 <br /> Octobcr 10, 2006 <br /> Page 2 <br /> 5. 7'he 2x8 deck joisis should bc shown to be pressure treated. Section 2304.11.5 <br /> 6. Fastcners into pre,sure heated materials should be specified to be either hot- <br /> dipped galvanized ur stainless stecL <br /> 7. In accordancc with Section ]O] l.l, exit signs should be sho�vn at the exit doors <br /> !eading to the exterior exit deck and exit doors leading to the interior stairway. <br /> The signs should be hardwired with battery backup. <br /> 8. Per Section 10063, thc egress system should be provided with emergency power <br /> at the exit doors Ieading to the exit stairs and exterior exit deck and the portion of <br /> exterior exit discharge immediately adjacent to the exit discharge doorways. <br /> 9. The permit application sho�vs the addition of a shower stall - however the plans <br /> show its removal. Showers for this building would need to comply with <br /> accessiblc stanJards. The intent should be clarifted. <br /> ]0. Details/elevations should be provided that show a minintum of one hand-wastt <br /> sink in a massagc room and one hcad-sink in the styling room is accessible. <br /> ANSI Scction 606 <br /> ] 1. It should be shown that the bottom edges of thc door vision lites are no higher <br /> than 43" above thc finished floor. ANSI Section 404.2.10 , <br /> I'lease provide a response lettrr, which shows where each item in this conection letter is <br /> addressed on the plan sct. <br /> Upon resubmission of the drawings, your application will be given priority and plan <br /> revicw will begin. <br /> All required submittals must be of sufficient detail and contain sufficient information to <br /> ensurc that thc proposcd structure will be constructcd in compliance with all adopted <br /> codcs. <br /> Sinccrcly, <br /> � <br /> 'i'ony . Lcc <br /> Permit Services Manager <br /> CC: �4ichael Wright,O�mcr <br />