My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1303 58TH ST SW 2016-01-01 MF Import
>
Address Records
>
58TH ST SW
>
1303
>
1303 58TH ST SW 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2017 12:02:33 PM
Creation date
4/17/2017 12:02:14 PM
Metadata
Fields
Template:
Address Document
Street Name
58TH ST SW
Street Number
1303
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Jeffrey S. Skutley <br /> Plan Check No. B45010 through B45027 (J 1 <br /> December 12, 1994 <br /> Page 3 of 4 <br /> 17. Enclosed usable space under stairs must be protected on the enclosed side as required for I- <br /> HR fire-resistive construction. Section 3306(1). See also Section 3309(0. <br /> 18. All doorways leading to accessible rooms shall have an unobstructed clear width of not less <br /> than 32 inches. Section 31060). This item applies to all doors within Type A and Type B <br /> units. <br /> 19. Accessible doors shall have maneuvering clearances per Section 3106(1)3. This item applies <br /> to all doors within Type A units. <br /> 20. Provide signage per Section 3106(p) to accessible parking spacing. Section 3103(b)4. <br /> 21. Controls, operating mechanisms and hardware shall be accessible in accordance with Section <br /> 3106(c). Section 3105(d)8. This item applies to Type A and Type B units. <br /> 22. Alarm systems shall include both audible and visible alarms and shall be located per Section <br /> 3105(d)9. <br /> 23. Three accessible parking stalls are required. Two must be reserved for the Type A units. <br /> Section 3107(b) <br /> 24. All ground floor units must be Type B units. <br /> 25. The patio doors in accessible units may have a '/2 maximum threshold. <br /> 26. Walls and floor separating dwelling units in the same building shall be of not less than 1-HR <br /> fire-resistive construction. Section 1202(b). <br /> 27. A Group R, Division 1 Occupancy more than two stories in height or having more than 3,000 <br /> square feet abo,+e the first story shall be of I-HR fire-resistive construction throughout <br /> Section 1202(b). <br />
The URL can be used to link to this page
Your browser does not support the video tag.