COMPLIANCE <br />REQUIRED Gr <br />0 <br />0 <br />f=_l <br />INSPECTION IMF`ORTANT: Supply Information and check appropriate circles In the shaded boxes. <br />APPROVED Disregard topics that done uvscrlbe your building orequlpment. DO NOT place checks In <br />the two left columns. <br />O rz Exhaust ventilaVin shall be provided for each dwelling unit (VIAO, S. 303): <br />11W <br />Location <br />Minimum at .25 w.g. MfrJmodel <br />Fan label CFM(.1W.G.) <br />Kitchen fan <br />100 CFM <br />Bathroom fan( <br />) <br />50 CFM <br />Bathroom fan( <br />) <br />50 CFM <br />Bathroom fan( <br />-) <br />50 CFM <br />Laundry fan <br />50 CFM <br />e Whole house fan <br />(choose one) <br />Q 50 CF d (1-2 bedrms) <br />]g 80 CFM (3 hedrms) . <br />Q 100 CFM (4 bedrms) <br />— b-U m Wj N <br />rao <br />Whole house fan: Location _ ki-t ___Sone rating—!'�_(s 1.5 if attic fan loser than 4'to <br />ceiling) <br />Q Whole house fan is Iisted/labled "for Continuous use". <br />Q Whole house fan wiring for control routed to central location (dehumidistat only). <br />Whole house fan also serves as a kitchen or bath spot fan. Q Yes Q No <br />(If a spot fan Is designated as a whole house fan, the capacity shall be the larger CFM requirement.) <br />Whole house fan shall run continuously: Kitchen rate 25CFM: Bath & laundry rate 20CFM <br />Integrated forced -air furnace ventilation (VIAO Code, S. 303.1.2(b)) shall be synchronized with a <br />whole house fan to supply fresh air to the dwelling: 'Q Yes ONO <br />Q • Wyes, a 6" diameter outside air inlet duct w/ motorized damper shall run from the building <br />exterior to the furnace return plenum and limit the ventiltion rate to between .35 .5 ACH, <br />Q Modifications to the above Integrated forced air system may require performance testing, in a <br />manner acceptable to the building official, to demonstrate .35 - ,5 Air Changes/Hour. <br />Mechanical ventilation fan ducts shall be i a' and properly sized (VIAO, Table 3.31. <br />]Fresh air shall be provided for each dwelling unit as follows (VIAQ, S. 302.6.1); <br />—Each_om: Tested, screened, controllable, through -wall port (i 4 Sq. in.) to the exterior. <br />ach recreatlon room: One wall port as specified for bedrooms. <br />Cher enclosed "habitable" rooms: One wall port as specified for bedrooms, <br />—Overall living area; One wall port as specified for bedrooms. <br />OR OCentral forced air furnace which delivers outside makeup air through the ducting system <br />ED s©Recessed lighting fixtures (S. 502.4.4) shall comply w/ one or more of the following: <br />Q IC rated, no slots or holes in cans, caulked or sealed between can and ceiling <br />)<11C rated with ]able certifying an ASTM E263 tested airleakage s 2.0 CFM <br />Q Any UL listed fixture enclosed by a 1/2" gypboard box or other manufactured box <br />w/ 112" clearance to combustables, and 3" clearanco to insulation. <br />Page 4 of 6 <br />WSEC Framing phase requirements: <br />Inspected by Date <br />