Laserfiche WebLink
Component Performance Path, pg. 2 Zones 4c/5b ENV-UAI <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2& R3 over: Revised Oct 2013 <br /> Project Address Underwood Gartland - Building a Date 05/18/2015 <br /> Fenestration Area as%gross above-grade wall area 7.7% Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area 1.3% Max.Target: 5.0% <br /> Notes: 1:If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target <br /> Area Adjustment of all applicable envelope elements will be calculated by the compliance form. <br /> Refer to Target Area Adjustments worksheet for this calculation. <br /> 2:Provide NFRC rated U-factor or default U-factor from Appendix A for the fenestration assembly <br /> thermal performance(combination of frame and glazing). <br /> 3:Fenestration that separates conditioned space from a non-conditioned or semi-conditioned <br /> Building Component Proposed UA Target UA <br /> Provide source of U-factor, page/plan#of assembly detail&ID U-factor x Area(A) =UA(U x A U-factor x Area(A)= UA(U x A) <br /> m N U=0.370 ID:Man Doors 0.370 1 378 139.9 0.37 378 139.9 <br /> 3 0 U= ID: Opaque Swing Doors U-0.37 <br /> 0 U= ID: <br /> ` U=0.0625 ID:9'x10'(R-16.00) 0.063 3600 225.0 0.37 5034 1862.6 <br /> 000 U=0.0656 ID:9'x10'w/windows(R-15.25) 0.066 450 29.5 Opaque rollup&sliding U-0.37 <br /> CL <br /> U=0.1299 ID:16'x16'ROIIup(R-7.70) 0.130 256 33.2 <br /> 0 <br /> U=0.0734 ID:12'X14'(R-16.00) 0.063 336 21.0 <br /> cr U=0.0734 ID:14'x14'w/windows(R-15.58) 0.064 392 25.2 <br /> U= ID: 0.30 <br /> U= ID: Non-Metal Frame U-0.30 <br /> o U= ID: <br /> Z U= ID: <br /> U=0.4 ID:Storefront Fixed 0.40 5179 2071.6 0.38 5179 1968.0 <br /> g U= ID: Metal Frame, Fixed U-0.38 <br /> ° V U= ID: <br /> U) (D <br /> W 2 U= ID: <br /> (D <br /> L Q U= ID: 0.40 <br /> `0° 0 U= ID: Metal Frame,Operable U-0.40 <br /> r <br /> (DU= ID: <br /> U= ID: <br /> (O; U=0.68 ID:Entrance 6'x7'&3x7 0.68 231 157.1 0.60 231 138.6 <br /> 2 U= ID: Metal Entrance Door U-0.60 <br /> ami U= ID: <br /> U= ID: <br /> n w U=0.30 ID:Skylight: U=0.30 0.30 2592 777.6 0.50 2592 1296.0 <br /> o, a U= ID: All types U-0.50 <br /> Y ~ U= ID: <br /> rn Q U= ID: <br /> Area UA Area UA <br /> Page 2 Subtotal 13414 3480 13414 5405 <br /> To comply: Page Subtotal 260239 16212 260239 14321 <br /> 1)Proposed Total UA shall not exceed Target Total UA. _F_ <br /> 2)Proposed Total Area shall equal Target Total Area. Total 273653 19692 27 3 6 5 3 19726 <br /> Component Performance Compliance (UA) UA COMPLIES <br />