My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2002 LOMBARD AVE 2017-06-13
>
Address Records
>
LOMBARD AVE
>
2002
>
2002 LOMBARD AVE 2017-06-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2017 2:52:30 PM
Creation date
6/13/2017 2:52:24 PM
Metadata
Fields
Template:
Address Document
Street Name
LOMBARD AVE
Street Number
2002
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The requirement for natural light allows taking light from adjoining rooms. "For the <br /> purpose of determining light requirements, any room shall be considered as a <br /> portion of an adjoining room when at least one-half of the area of the common wall <br /> is open and unobstructed and provides an opening of not less than one-tenth of the <br /> floor area of the interior room but not less than 25 square feet (2.3m2).,, <br /> The proposed bedroom addition does not provide"at least one-half of the area of <br /> the common wall" as being open and unobstructed (assuming a 10' wide wall 8'tall, <br /> 40 square feet required. Therefore not enough natural light is provided from the <br /> bedroom for the den. Artificial light may be used per the exception to section <br /> R303.1 Natural Light. (As follows.) <br /> "The glazed area need not be installed in rooms where artificial light is provided <br /> capable of producing an average illumination of 6 footcandles (65 LUX) over the area <br /> of the room at a height of 30 inches (762mm) above the floor level." <br /> Provide lighting schedule if the exception is used. <br /> Ventilation requirements are in section M1507.3 IRC for interior spaces. <br /> 6. Provide foundation ventilation calculation. Show size and location of foundation <br /> vents on foundation plan. <br /> 8. Specify on the plans, the minimum size of headers required for the openings in the <br /> existing exterior walls considering the additional weight from the roof of the <br /> addition. <br /> 9. There does not appear to be a call-out on the plans for the required R-10 rigid <br /> insulation. <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincer/ilma�n <br /> Jeff H <br /> Development Technician <br /> 425-257-8976 <br /> Email: jheilman@ci.everett.wa.us <br /> S:\lCommon\Clerical\JHeilman\Bl4l2-015 2002 Lombard Ave .doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.