Laserfiche WebLink
. <br /> • • • • <br /> 2012 Washington State Energy Code Compliance Forms for Commercial,Group R1,and>3 story R2 and R3 Revised June 2013 <br /> Project Address People's Bank Date 5/22/2015 <br /> The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 <br /> WSEC. NOTE:Define print area in Excel prior to printing MECH-CHK pages. <br /> Applicability Code Section Code Provision Information Required Location Building Department <br /> (yes,no,na) on Plans Notes <br /> GENERAL PROVISIONS <br /> Equipment Sizing&Performance <br /> YE$ C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Attached <br /> Cha ter 3 <br /> YE$ C403.2.2 Equipment and system Output capacity of heating and cooling equipment and systems do not M 1.0 <br /> sizin exceed calculated loads,note exce tions taken <br /> C403.2.5 Minimum ventilation Ventilation(natural or mechanical)provided per IMC;indicate mechanical <br /> YE$ ventilation is ca able of bein reduced to minimum requirement er IMC M 1.0, M 1.1 <br /> C403.2.3& Equipment minimum Provide equipment schedules or complete MECH-SUM tables with type, <br /> C403.2.3.2& efficiency capacity,efficiency,test standard(or other efficiency source)for all <br /> YE$ C4032.12.1 mechanicalequipment M1.1 <br /> YE$ C4032.13 Electric motor e�ciency Provide equipment schedule with hp.rpm,efficiency for all motors;note M 1.1 <br /> exce t. <br /> YES C4032.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table M 1.1 <br /> C403.2.10.1 1 <br /> YES C403.2.10.3 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency M1.1 <br /> &C403.2.13 re . <br /> N/A C403.2.3 Maximum air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit <br /> ca acit <br /> C403.2.1 Non-standard water-cooled Full-load and NPLV values for water-cooled centrifugal chiller adjusted for <br /> N/A chillers non-standard operational conditions <br /> C403.2.12.1. Centrifugal fan cooling Large capacity cooling towers with centrifugal fan(s)meet efficiency <br /> N/A towers requirements for axial fan open circuit cooling towers <br /> N A C403.2.3 heatetl air furnace and unit Indicate intermittent ignition or IID,flue/draft damper&jacket loss <br /> � <br /> N A C403.2.3.3 Packaged electric List equipment required to be heat pumps on schedule <br /> � heatin /coolin e ui ment <br /> N/A C403.2.3.4 Humidification Indicate method of humidifcation(note requirements for systems with <br /> economizer <br /> HVAC System Controls&Criteria <br /> YE$ C403.2.4.1 Thermostatic conlrols Indicate locations ofthermostatic control zones on plans,including M1.0 <br /> erimeter s stems <br /> YES C403.2.4.1.1 Heat pump supplementary Indicate staged heating(compression/supplemental)&outdoor lock-out M 1.0 <br /> heat tem <br /> YE$ C4032.42 Setpoint overlap Indicate 5°F deadband minimum for systems controlling both heating& M 1.0 <br /> deadband coolin <br /> C4032.4.3 Automatic setback and Indicate zone t-stat controls with required automatic setback&manual <br /> YE$ shutdown override M 1.0 <br /> YES C4032.4.3.3 Automatic(optimum)start Indicate system controls that adjust equip start time lo match load <br /> conditions M 1.0 <br /> C402.4.5.2& Indicale localion of OSA,exhaust,relie(and return air dampers;include <br /> YES C403.2.4.4 Dampers AMCA rated leaka e and control t e motorized or ravit note M 1.0 <br /> N/A C4032.11 Heating outside a building Indicate radiant heat system and occupancy controls <br /> N/A C403.2.4.5 Snow melt systems Indicale shut-off controls based on outdoor conditions <br /> N/A C403.2.4.6 Combustion heating Indicate modulating or staged control <br /> e ui ment <br /> N/A C403.2.4.7 Group R1 hotel/motel Indicate method for guest room automatic setback&set-up of 5°F <br /> s stems minimum <br /> N/A C403.2.4.8/ Group R2/R3 dwelling unit Indicate S-2 programmable thermostats in primary spaces with minimum of <br /> s stems two setback eriods;note exce tions taken <br /> N/A C403.2.5.1 Demand controlled Indicate high-occupancy spaces and systems requiring DCV <br /> ventilation <br /> N/A C4032.5.2 Occupancy sensors Indicate spaces requiring occupancy-based system control and method;or <br /> alternate means rovided to automaticall reduce OSA when artiall <br /> Enclosed loading Indicate enclosed Ioading dock and enclosed parking garage ventilation <br /> / C4032.5.3 dock/parking garage <br /> N A ventilation system activation and control meihod <br /> N/A C4032.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air;indicate make-up air source <br /> and conditionin method <br /> Indicate lab exhaust systems requiring heat recovery,method&effciency; <br /> N/A C4032.5.42 Laboratory exhaust systems or altemative method taken(VAV,semi-conditioned makeup,or CERM <br /> calculation <br /> C4032.6.1 Energy recovery- Indicate ventilation systems requiring ER.method&efficiency;note <br /> N/A ventilation systems exceptions <br /> (�J�/� C4032.6.2 Energy recovery- Indicate on-site steam heating systems requiring energy recovery <br /> condensate s stems <br /> C403.2.6.3 Energy recovery- Indicate remote refrig.condensers requiring ER and use of captured <br /> N�A condenser s stems ener <br /> b . <br /> �� r� <br />