v. Sheet No. 115 (Drawing S3.23) <br /> 3. Replace Sheet No. 145 with attached: Drawing S3.53 has been revised with run-off <br /> diversion plate detail and handhole cover plate detail. <br /> 4. On Sheet No. 34 "Plant Schedule", Delete "HHI — Hypericum Hidcote (Hidcote St. <br /> Johnswort) — 2 Gal pots— 7 EA" (Drawing L1.05). <br /> CLARIFICATIONS <br /> Question 1 <br /> Will there be a Division 26 Specification Section issued for the Electrical work (Conduit, Wiring, <br /> Distribution Equipment, Interior Lighting, etc.) that is done inside of the Elevator Tower? <br /> Answer—No additional Division 26 specifications will be provided. <br /> Question 2 <br /> Could you provide a description of Bid Items A95 and B7, so we know what's included in each <br /> one? Or, were you just looking for us to come up with a total cost of the steel and apply 80% <br /> of the cost to Bid Item A95 and 20% of the cost to Bid Item B7? <br /> Answer—Determine a single lump sum price for all Structural Low Alloy Steel, Grade 50 or <br /> 50W, per Sheet 0.01. 80% will be paid under bid item A95 and 20% will be paid under Bid <br /> Item B7. <br /> Question 3 <br /> Can 1.8M sectional casing be used as the temporary casing for the 6'diameter drilled shafts? <br /> Answer—Yes. <br /> Question 4 <br /> Reference S7.01-S7.03. We assume all SD, CS, and CSFM pipe support material shown on these <br /> drawings is to be provided per Division 7 Special Provisions and paid for under Bridge <br /> Supported Steel Pipe Bid Items A41, A67, and A69. Please confirm. <br /> Answer—Confirmed. SD, CS, and CSFM pipe support material will be paid for under Bid Items <br /> A41, A67, and A69 respectively. <br /> Question 5 <br /> Reference S3.45, Grating Walkway Detail. Please provide additional information on the type of <br /> walkway grating required (e.g. bearing bar and cross bar size and spacing). <br /> Answer—See note below "Grating Walkway Detail". Contractor to size grating appropriately <br /> for the span, and submit design to the Engineer for approval. <br /> Question 6 <br /> Reference S3.03 (& similar). The HS bolts at the box truss members cannot be torqued from <br /> the inside as there is insufficient clearance for the torquing equipment (as little as 12-1/2" <br /> between chord webs). We assume in these cases, the nuts may be placed on the outside of the <br /> connection to facilitate torquing. Please confirm. <br /> Answer—Nuts are to be placed inside. If no industry available torque or shear wrench can <br /> work due to space limitations then a consistent pattern must be established between the <br /> engineer and contractor regarding a nut pattern visible from the outside. Random reversing of <br /> nuts and bolts is not permitted. <br /> City of Everett Addendum No. 2 <br /> Project Bid <br /> Grand Avenue Park Bridge Page 3 <br />