Plan Review Comments is <br /> Tenant Improvement: 131703-0 8 <br /> SOUTH POINT PLAZA LLC/PAPA MURPHYS <br /> Papa Murphy's Pizza#WA188 <br /> 10117 Evergreen Way,#A <br /> Everett,WA 98204 <br /> Accessibility <br /> 1. The following should be shown on the drawings: <br /> a. Door hardware should be shown to be accessible for the new toilet room, per IEBC section 410.7. <br /> Understand and will comply,see note added to Door Hardware Schedule on sheet A1.0. <br /> b. The toilet paper dispensers should be shown on the toilet room elevations to meet the requirements of ICC- <br /> A117.1-2009 section 604.7. Understand and will comply,see detail 16 on sheet A0.1. <br /> c. Grab bars and sinks should be shown in elevation to meet the minimum requirements of ICC-A117.1-2009 <br /> Figures 604.5.1, 604.5.2, 604.3, and section 606.3. Understand and will comply,see detail 1 &3 on sheet <br /> A0.2 <br /> Energy <br /> 1. Please summarize energy compliance for this submittal and deferred submittals using the checklist in WSEC C103.2 <br /> as a guide for additional information required on the drawings.An assembly occupancy would be a change in use, <br /> per WSEC section C505. RESPONSE: Energy compliance for lighting is included in the resubmittal. Notes to <br /> show compliance with mandatory requirements are included on sheet E2.0 and Compliance forms are shown <br /> on Sheet E4.0 <br /> 2.Alterations which replace more than 50%of the luminaires have to comply with lighting controls, per WSEC C503.6. <br /> a. Please include a calculated lighting summary from the forms available on NEEC.NET to verify compliance for the <br /> interior lighting power allowances per WSEC table C405.2(1). RESPONSE: Calculated lighting summary and <br /> compliance forms are included on sheet E4.0. <br /> b. Please include actual code section language on the building drawings for interior lighting controls, sensors, and all <br /> other methods of compliance covered in electrical power and lighting systems per WSEC sections C405 and C503.6. <br /> Mandatory requirements for controls,switching and sensors are listed on sheet E2.0 <br /> 3. Compliance with the building thermal envelope requirements should be shown in section and summarized on the <br /> drawings, per WSEC section C503.1. Please indicate the method of building envelope compliance by completing a <br /> total UA alternative worksheet, or provide a completed prescriptive worksheet to include detailed R-Values of new <br /> exterior walls, roof-ceiling details, slab on grade and foundation details, per WSEC section C402.1. RESPONSE: Per <br /> Section 503.: "Alterations to an existing building, building system or portion thereof shall conform to the <br /> provisions of this code as they relate to new construction without requiring the unaltered portions of the <br /> existing building or building system to comply with this code. No alterations to the building envelope are <br /> proposed in this submittal and compliance of the unaltered portions is not required. <br /> a. Please indicate the U values of all new fenestration to meet energy code requirements,to include man doors and <br /> windows, per WSEC C402.1.4 and C402.4. RESPONSE: N/A, no new doors or windows. <br /> 4. All compliance forms referenced are available on neec.net. Response: Noted. Completed compliance forms for <br /> interior lighting and controls are included on sheet E4.0 <br /> Deferred Mechanical <br /> 1. Please show toilet room fan cfm per IMC table 403.3.1.1, as amended by WA State. Noted.Shown on sheet M1.0. <br /> 2.The mechanical permit has not been reviewed at this time based on missing information discussed at the time of <br /> submittal. <br /> 3. Cut sheet is required for the freezers to show compliance with the energy code, per WSEC 403.5.3 condenser heat <br /> recovery,and C410. No freezer installed,cooler only. Cooler cut sheet attached. <br /> END <br /> Please feel free to call or email if you have any further questions regarding this project. <br /> Respectfully, <br /> Craig D.Gilbert <br /> Job Captain <br /> PM Design Group,Inc. <br /> 16219 SE 12th Street,Suite 202 <br /> Vonrolw- WA. 98683 <br /> P:360.719.1953 <br /> F.360.719.1955 <br /> E.cgilbert@pmdginc.com <br /> Page 2 of.2 <br />