My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10117 EVERGREEN WAY PAPA MURPHYS 2018-10-31
>
Address Records
>
EVERGREEN WAY
>
10117
>
PAPA MURPHYS
>
10117 EVERGREEN WAY PAPA MURPHYS 2018-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2018 11:49:36 AM
Creation date
10/20/2017 10:52:05 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10117
Tenant Name
PAPA MURPHYS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Review Comments is <br /> Tenant Improvement: 131703-0 8 <br /> SOUTH POINT PLAZA LLC/PAPA MURPHYS <br /> Papa Murphy's Pizza#WA188 <br /> 10117 Evergreen Way,#A <br /> Everett,WA 98204 <br /> Accessibility <br /> 1. The following should be shown on the drawings: <br /> a. Door hardware should be shown to be accessible for the new toilet room, per IEBC section 410.7. <br /> Understand and will comply,see note added to Door Hardware Schedule on sheet A1.0. <br /> b. The toilet paper dispensers should be shown on the toilet room elevations to meet the requirements of ICC- <br /> A117.1-2009 section 604.7. Understand and will comply,see detail 16 on sheet A0.1. <br /> c. Grab bars and sinks should be shown in elevation to meet the minimum requirements of ICC-A117.1-2009 <br /> Figures 604.5.1, 604.5.2, 604.3, and section 606.3. Understand and will comply,see detail 1 &3 on sheet <br /> A0.2 <br /> Energy <br /> 1. Please summarize energy compliance for this submittal and deferred submittals using the checklist in WSEC C103.2 <br /> as a guide for additional information required on the drawings.An assembly occupancy would be a change in use, <br /> per WSEC section C505. RESPONSE: Energy compliance for lighting is included in the resubmittal. Notes to <br /> show compliance with mandatory requirements are included on sheet E2.0 and Compliance forms are shown <br /> on Sheet E4.0 <br /> 2.Alterations which replace more than 50%of the luminaires have to comply with lighting controls, per WSEC C503.6. <br /> a. Please include a calculated lighting summary from the forms available on NEEC.NET to verify compliance for the <br /> interior lighting power allowances per WSEC table C405.2(1). RESPONSE: Calculated lighting summary and <br /> compliance forms are included on sheet E4.0. <br /> b. Please include actual code section language on the building drawings for interior lighting controls, sensors, and all <br /> other methods of compliance covered in electrical power and lighting systems per WSEC sections C405 and C503.6. <br /> Mandatory requirements for controls,switching and sensors are listed on sheet E2.0 <br /> 3. Compliance with the building thermal envelope requirements should be shown in section and summarized on the <br /> drawings, per WSEC section C503.1. Please indicate the method of building envelope compliance by completing a <br /> total UA alternative worksheet, or provide a completed prescriptive worksheet to include detailed R-Values of new <br /> exterior walls, roof-ceiling details, slab on grade and foundation details, per WSEC section C402.1. RESPONSE: Per <br /> Section 503.: "Alterations to an existing building, building system or portion thereof shall conform to the <br /> provisions of this code as they relate to new construction without requiring the unaltered portions of the <br /> existing building or building system to comply with this code. No alterations to the building envelope are <br /> proposed in this submittal and compliance of the unaltered portions is not required. <br /> a. Please indicate the U values of all new fenestration to meet energy code requirements,to include man doors and <br /> windows, per WSEC C402.1.4 and C402.4. RESPONSE: N/A, no new doors or windows. <br /> 4. All compliance forms referenced are available on neec.net. Response: Noted. Completed compliance forms for <br /> interior lighting and controls are included on sheet E4.0 <br /> Deferred Mechanical <br /> 1. Please show toilet room fan cfm per IMC table 403.3.1.1, as amended by WA State. Noted.Shown on sheet M1.0. <br /> 2.The mechanical permit has not been reviewed at this time based on missing information discussed at the time of <br /> submittal. <br /> 3. Cut sheet is required for the freezers to show compliance with the energy code, per WSEC 403.5.3 condenser heat <br /> recovery,and C410. No freezer installed,cooler only. Cooler cut sheet attached. <br /> END <br /> Please feel free to call or email if you have any further questions regarding this project. <br /> Respectfully, <br /> Craig D.Gilbert <br /> Job Captain <br /> PM Design Group,Inc. <br /> 16219 SE 12th Street,Suite 202 <br /> Vonrolw- WA. 98683 <br /> P:360.719.1953 <br /> F.360.719.1955 <br /> E.cgilbert@pmdginc.com <br /> Page 2 of.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.