Laserfiche WebLink
Master Controller Selection Information Continued <br /> Master Controller Accessories <br /> 4100-2300 Expansion Bay Assembly; order for each required expansion bay(not required for 4100-9121) <br /> 4100-2303 Legacy Module Stabilizer Bracket, used when expansion bays have legacy slot style modules <br /> Expansion Bay Upgrade Kit for mounting 4100ES style(4"x 5"modules)in existing 4100 style panels; <br /> 4100-2301 Note:When using this kit to upgrade a 4100+transponder, a 4100-0620 Transponder Interface Card(TIC)is also <br /> required for communications to the 4100ES module <br /> Master Controller Upgrades for Existing 4020 Series Fire Alarm Control Panel <br /> Model Description <br /> 4020 Master Controller Upgrade to 4100ES; Includes New Master Controller with LCD&operator interface assembly, <br /> 4100-9833 8 VDC Converter and RUI Interface in a single bay cabinet with locking glass door and retainer; mounts as an adjunct <br /> panel close-nippled to existing 4020 cabinet;also includes 8 VDC box-to-box power and communications harness and <br /> solid filler panel for the existing 4020 Master Controller bay <br /> Module Selection Information <br /> Communication Modules <br /> Model Description Size Supv. Alarm <br /> 4100-6078 For Master Controller; mounts in Slot 3 Modular Network Interface;each requires 1 Slot 46 mA 46 mA <br /> 4100-6061 For Redundant Master Controller two media modules(below) 1 Slot 46 mA 46 mA <br /> 4100-6056 Wired Media Module Select two media cards as required; mounts on N.A. 55 mA 55 mA <br /> 4100-6057 Fiber Optic Media Module 4100-6078 or 4100-6061;Class B or Class X operation N.A. 25 mA 25 mA <br /> 4100-6047 Building Network Interface Card(BNIC), refer to data sheet S4100-0061 for details 2 Blocks 291 mA 291 mA <br /> 4100-6055 Network Access Dial-in Service Modem, mounts to 4100-6078 or 4100-6061 Network N.A. 60 mA 60 mA <br /> Interface Card, requires telephone line connection <br /> 4100-1291 Remote Unit Interface Module(RUI); up to three maximum per control panel 1 Slot 85 mA 85 mA <br /> 4100 6030 Service Port Modern, local panel access only,mounts to Master Controller Module, N.A. 70 mA 70 mA <br /> requires telephone line connection, accesses same information as front panel port <br /> 4100-6031 City Circuit,with disconnect switches For use with SPS N.A. 20 mA 36 mA <br /> 4100-6032 Select one per City Circuit,w/o disconnect switches only, not RPS N.A. 20 mA 36 mA <br /> SPS(fits on SPS) <br /> 4100-6033 Alarm Relay, 3 Form C relays,2 A @ 32 VDC;for SPS or RPS N.A. 15 mA 37 mA <br /> 4100-6101 Physical Bridge,Class B, includes 1 modem module and 2 wired modules 1 Slot 210 mA 210 mA <br /> 4100-6102 Physical Bridge,Class X,includes 2 modem and 2 wired modules 2 Slots 300 mA 300 mA <br /> 4100-6038 Dual Port RS-232 with 2120 interface(slot module) 3 maximum of RS-232 type 1 Slot 132 mA 132 mA <br /> 4100-6046 Dual Port RS-232 standard interface(4 x 5 module) modules per panel 1 Block 60 mA 60 mA <br /> 4100-6045 Decoder Module 3 Slots 85 mA 163 mA <br /> 4100-6048 VESDA Aspiration System Interface 1 Slot 132 mA 132 mA <br /> 4100-6052 DACT, Point or Event Reporting; 1 shipped unless 4100-7908 is selected; 2 max. per 1 Slot 30 mA 40 mA <br /> system; includes 2,2080-9047 cables, 14 ft(4.3 m)long, RJ45 plug and spade lugs <br /> Expansion,System and Remote Power Supplies and Accessories(Canadian models have low battery cutout) <br /> Model Voltage/Listing Description Size Supv. Alarm <br /> 4100-5101 120 VAC UL Expansion Power Supply(XPS);9 A output,3 built-in <br /> 4100-5103 120 VAC,Canadian ULC Class A/B NACs; NAC operation is same as SPS,see 2 Blocks 50 mA 50 mA <br /> 4100-5102 220-240 VAC UL page 5 for details <br /> 4100-5115 NAC Expansion Module,3 NACs, Class A/B, mounts on XPS only N.A. 25 mA 25 mA <br /> 4100-5111 120 VAC UL Additional System Power Supply(SPS);9 A power <br /> 4100-5112 120 VAC,Canadian ULC supply/charger with 250 point IDNet channel, 3 Class 4 Blocks 175 mA 185 mA <br /> 4100-5113 220-240 VAC UL NB NACs, add ZDNet device currents separately <br /> 4100-5125 120 VAC UL Remote Power Supply(RPS);9 A power <br /> 4100-5126 120 VAC,Canadian ULC supply/charger similar to SPS except no IDNet channel 4 Blocks 150 mA 185 mA <br /> 4100-5127 220-240 VAC UL or City Circuits;will accept one 4100-6033 <br /> Continued on next page <br /> S4100-0031-30 12/2014 <br /> 11) <br />