Laserfiche WebLink
Module Selection Inform•tion Continued <br /> Expansion, System and Remote Power Supplies and Accessories (Continued) <br /> Model Description Size Current <br /> 4100-5152 12 VDC Power Option,2 A maximum 1 Block 1.5 A maximum <br /> 4100-0156 8 VDC Converter, required for multiple Physical Bridge Modules,3 A maximum 1 Block included w/loads <br /> 4100-0636 Box Interconnection Harness Kit(non-audio); order one for each close-nippled cabinet <br /> 4100-0638 4100 Slot Module Additional 24 VDC Harness; need when 4100 Slot module requirements exceed 2 A from SPS <br /> 8 Zone Initiating Device Circuits* Expansion Signal Module and Options(1.5 A Class B except as noted) <br /> Model Type I Supv. Alarm Model Description Supv. Alarm <br /> ---> 4100-5005 Class B 75 mA 195 mA 4100-5116 Converts 1 NAC in to 3 NACs out; 1 Block size 18 mA 80 mA <br /> 4100-5015 Class A 75 mA 195 mA 4100-1266 Expands 3 NACs to 6 select one;mounts 0.6 mA 60 mA <br /> *IDC Modules are 1 Slot size 4100-1267 Converts 3 NACs to Class A on 4100-5116 0.6 mA 30 mA <br /> Addressable Interface Modules (refer to location reference on pages 8 and 9) <br /> Model Description Supv. Alarm <br /> no devices 50 mA 60 mA <br /> IDNet 2 Module,250 point capacity;electrically isolated output with two short <br /> circuit isolating Class B or Class A output loops, 1 block;standard on EPS with 50 devices 90 mA 150 mA <br /> 4100-3109" ZDNet 2 Module; alarm currents for 50 and above devices includes 20 device <br /> 125 devices 150 mA 225 mA <br /> LEDs in alarm <br /> 250 devices 250 mA 350 mA <br /> ZDNet 2+2 Module,250 point capacity; electrically isolated output with four no devices 50 mA 60 mA <br /> short circuit isolating Class B or Class A output loops, 1 block; mounts in 50 devices 90 mA 150 mA <br /> 4100-3110* expansion bay or available master controller bay module locations only, not — -- <br /> applicable for EPS mounting;alarm currents for 50 and above devices includes 125 devices 150 mA 225 mA <br /> 20 device LEDs in alami 250 devices 250 mA 350 mA <br /> 4100-3111* IDNet Short Circuit Isolating Loop Output Module;mount up to two on a 4100-3109 module;for use with 4100-3109 <br /> modules; this option is for aftermarket field installation only <br /> *Note: Loading per ZDNet device(no LEDs on)=0.8 mA supervisory and 1 mA alarm. <br /> Each IDNet 2 and IDNet 2+2 Short Circuit Isolating Loop Output can be individually controlled for system diagnostics and <br /> can be assigned a public poin:for Fire Alarm Network annunciation. <br /> Model Description Supv. Alarm <br /> MAPNET II Module, 127 point capacity, add devices Module without devices 255 mA 275 mA <br /> 4100-3102 separately; Module size=2 Slots; <br /> Loading per MAPNET II device=1.7 mA Fully loaded module,total 471 mA 491 mA <br /> Isolator Module for MAF'NET II communications; converts a single connected SLC <br /> 4100-3103 into four isolated outputs selectable as Class A or Class B; up to two Isolator Modules 50 mA 50 mA <br /> can be connected to one SLC; Module size= 1 Slot; <br /> NOTE:Compatible with MAPNET II Remote Isolators only <br /> Relay Modules; Nonpower-limited (for mounting in expansion bay only, refer to location reference on pages 8 and 9) <br /> Model Description Resistive Ratings Inductive Ratings Size Supv. Alarm <br /> 4100-3202 4 DPDT w/feedback 10 A 250 VAC 10 A 250 VAC 2 Slots 15 mA 175 mA <br /> 4100-3204 4 DPDT w/feedback 2 A 30 VDCNAC 1/2 A 30 VDC/120 VAC 1 Block 15 mA 60 mA <br /> 4100-3206 8 SPDT 3 A 30 VDC/120 VAC 1-1/2 A 30 VDC/120 VAC 1 Block 15 mA 190 mA <br /> Current Calculation Notes: <br /> 1. To determine total supervisory current, add currents of modules in panel to base system value and all external loads powered <br /> by panel power supplies. <br /> 2. To determine total alarm current,add currents of modules in panel to base system alarm current and add all panel NAC loads <br /> and all external loads powered from panel power supplies. <br /> Continued on next page <br /> S4100-0031-30 12/2014 %I� .' <br />