Module Selection Information (Continued)
<br /> End User Programming Software(requires 4100-8802)
<br /> Model Description
<br /> 4100-8802 Programming Software(select)
<br /> End User Programming Software Selection(select maximum of one each from below)
<br /> Model Description
<br /> 4100-0292 Custom Labels Editing;allows editing of 40 Character Custom Labels for non-system user points
<br /> Access Level/Passcode Editing; allows user to re-assign Access Levels and Passcodes for each display function;
<br /> 4100-0296 Acknowledge,Alarm Silence,System Reset, Point Enable/Disable,WALKTEST Enable/Disable,Clear History Logs,
<br /> Change Time&Date,etc.
<br /> 4100-0295 Port Vectoring Setup and Control;Allows vectoring of events to PC Annunciator,Printers, LCD Annunciators,etc.
<br /> WALKTEST Configuration Setup and Control;Allows user to create or edit WALKTEST groups used to test system
<br /> 4100-0298 initiating devices and signals by a single person,these groups allow an inspector to conduct a one-person
<br /> WALKTEST in a specific area of a building(or different buildings),and limit the activation of the building signals to
<br /> only the intended area; up to 8 WALKTEST groups are supported
<br /> Miscellaneous Accessories
<br /> Model Description
<br /> 4100-1279 Single blank 2"display cover;4100-2302 provides a single plate for a full bay
<br /> 4100-9856* 4100ES Canadian French Appliqué Kit;Simplex,4100ES, Controle Incendie
<br /> 4100-9857* 4100ES English Appliqué Kit; Simplex,4100ES,Fire Control
<br /> 4100-9858* 4100ES InfoAlarm Remote Display English Appliqué Kit; Simplex,Operator Interface,4100ES
<br /> 4100-9859* 4100ES InfoAlarm Remote Display Canadian French Appliqué Kit; Simplex, Interface de l'operateur,4100ES
<br /> 4100-9868 Special Purpose Appliqué Kit:Simplex,Elevator Recall Control and Supervisory Control Unit,4100ES
<br /> 4100-9869 Special Purpose Appliqué Kit:Simplex,Sprinkler Waterfow and Supervisory Station,4100ES
<br /> 4100-9835 Termination and Address Label Kit(for module marking);provides additional labels for field installed modules
<br /> 4100-6029 Smoke Management Application Guide; required for UUKL listing
<br /> 4100-6034 Tamper Switch,one per cabinet assembly if required;monitors solid door for panels with solid door;monitors the
<br /> internal retainer panel for panels with glass door(not the glass door);has a built-in addressable IDNet IAM
<br /> Series resistor for WSO, IDCs(N.O.water flow and tamper on same circuit,wires after water flow and before tamper)
<br /> 2081-9031 470 0, 1 W,encapsulated,two 18 AWG leads(0.82 mm2),2-1/2"L x 1-3/8"W x 1"H(64 mm x 35 mm x 25 mm)
<br /> *Note: 4100ES English Appliqués are included with 4100ES Upgrade and Retrofit Kits for mounting 4100ES in 4100,2120,2001,
<br /> and Autocall back boxes so that upgrades can be easily identified as 4100ES.4100ES Appliqué Kits are available for
<br /> applications such as to update Remote InfoAlarm Displays connected to a panel that was upgraded to 4100ES or for an
<br /> existing 41000 when the New Master Controller is upgraded to 4100ES and only a software upgrade is required.When
<br /> required,French appliqués are ordered separately.
<br /> Expansion Bay Module Loading Reference
<br /> Slot 1 Slot 2 slot 3 slot 4 slot 5 slots Slot 7 Slot 8 Description Mounting
<br /> 8 ZDNet 2,ZDNet 2+2 Modules 1 Block
<br /> 4,2 A Relays 1 block
<br /> ON
<br /> 4,10 A Relays power-limited 4",2 slots
<br /> Block A Block C Block E Block G
<br /> 8,3 A Relays 1 block
<br /> VESDA Interface 2",1 Slot
<br /> Class B IDC 2",1 Slot
<br /> Class A IDC 2",1 Slot
<br /> MAPNET II Module 4",2 Slots
<br /> MAPNET II/IDNet Isolator 2",1 Slot
<br /> Class B Physical Bridge 2",1 Slot
<br /> Block B Block D Block F Block H Class X Physical Bridge 4",2 Slots
<br /> Decoder Module 6",3 Slots
<br /> 8 ] System or Remote Power Supply Blocks E,F,G&H
<br /> ONLY
<br /> Expansion Bay Chassis Expansion Power Supply Blocks G&H ONLY
<br /> Size Definitions:Block=4"W x 5"H(102.mm x 127 mm)card area NAC Expansion Module On XPS ONLY
<br /> Slot=2"W x 8"H(51 mm x 203 mm)motherboard with daughter card — /
<br /> S4100-0031-30 12/2014 ��