� <br /> , --_ <br /> � CORRECTIONS FOR BUILDING PLAN REVIEW— RESPONSE Page 2 �` - � <br /> : � <br /> PERMIT NUMBER B1703-007 <br /> DSE4 - 6611 ASSOCIATED BLVD <br /> b. P/ease summarize total occupant load count by occupancy and floor area,per IBC table <br /> 1004.1.2 <br /> c. Please inc/ude plumbing fixture ca/culations per IBC Chapter 29 Table 2902.1, as amended by <br /> the State of Washington. <br /> Response: <br /> Occupancy load calculations have been added to A0.00 under Project Data. Additional <br /> information supporting occupant load can be found on sheet A1.00 <br /> ,/ a. The drive lanes have been revised to type S-2 occupancy. Refer to 1/A1.00 <br /> b. Refer to sheet A1.00 under the heading "CODE SUMMARY" <br /> c. Refer to sheet A1.00 under the heading "PLUMBING FIXTURE REQUIREMENTS" <br /> 2. Please inc/ude allowable height and area calculations for the three occupancies, and indicate whether <br /> the occupancies are accessory, and whether they are separated or non-separated, per IBC section <br /> 508. <br /> Response: <br /> The occupancies and code research based on existing type III-B construction and per IBC <br /> Cha ter 5 are as follows: <br /> ALLOWABLE HEIGHT ALLOWABLE AREA ACCESSORY SEPARATION <br /> S-1 75 feet 70 000 sf No Non-se arated <br /> S-2 75 feet 104 000 sf No Non-se arated <br /> B 75 feet 76 000 sf No Non-se arated <br /> A-2 75 feet 38 000 sf Yes Non-se arated <br /> The requirements per occupancy B* are most restrictive and will govern. Based on IBC Table <br /> 504.3 &506.2, the allowable height is 75 feet above grade plane and the allowable area is <br /> 76,000 sf. <br /> This building has >30 ft open space on all four sides and qualifies for a 75% increase to <br /> allowable area per IBC 506.3 Frontage increase. This results in a total allowable area of <br /> (76,000 sf x 1.75) 133,000 sf. <br /> *The A-2 occupancy is accessory to the main occupancy and is, therefore, not considered <br /> when determining which occupancy requirements govern. (873 sf/90,734 sf <10%) <br /> 3. P/ease show the fol%wing on the drawings: <br /> a. A discernible path of egress should be shown with illuminated exit signs,per IBC section <br /> 1011.1, to indude the existing building and mezzanines. <br /> b. Emergency lighting, per IBC section 1006.1 <br /> c. Specific signage at the main entrance door and the exit doors to indicate that these doors wi/l <br /> be open during business hours,per IBC section 1010.1.9.3, item 2.2 <br /> d. The door schedule should indicate that any locking devices on these doors are readi/y <br /> distinguishable as being locked, <br /> Response: <br /> a. Exit access path and exit signs are shown on drawing 1/A1.00. The mezzanine <br /> floor plan has been added to the code plan sheet. Refer to 2/A1.00 <br /> b. Emergency lighting is included in the electrical permit drawings. Note has been <br /> added to RCP GENERAL NOTES on sheet A7.10 to reference IBC requirement <br /> c. Keynote FP-24 has been added to 1/A3.10 to indicate required egress signage <br /> d. Keynote FP-24 has been added to 1/A3.10 to indicate that locking devices must <br /> be readily distinguishable as being locked. Notation also added to DOOR <br /> HARDWARE schedule on A9.00 <br />