My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3231 BROADWAY 2018-01-11
>
Address Records
>
BROADWAY
>
3231
>
3231 BROADWAY 2018-01-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2018 2:35:26 PM
Creation date
1/11/2018 2:34:56 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3231
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, , <br /> ���, <br /> � � _ <br /> PUBL/C I�l/O/�/�.S g�j;;,!� �.�;� �ti�,��; a <br /> ��✓i���r ' <br /> � , : <br /> � <br /> � <br /> November 13, 2015 <br /> Mr. James Haugen <br /> 9917 N Davies Road <br /> Lake Stevens, WA 98258 <br /> Project: Parking, Occupancy, and Enclosure <br /> Owner: James Haugen <br /> Job Address: 3231 Broadway <br /> Plan Review: BW1504-003 <br /> RE: Fourth Corrections Letter <br /> Jim, <br /> Please submit two sets of revisions with a response letter indicating how all corrections are <br /> resolved on the plan set. The drawings and corrections letter response can be sent by e-mail to <br /> me. All required submittals must be of sufficient detail and information to ensure that the <br /> proposed structure will be constructed in compliance with all adopted codes. These comments <br /> address building issues only. <br /> General <br /> ✓1. Please cloud and add a revision date to the drawings for revisions required by this <br /> corrections letter. <br /> ,/2. The Planning Department had requested square footaQes to be shown on the basement <br /> and first floor plans, as was submitted to the Hearing Examiner. Please update the <br /> drawings with this information. If you have questions, please contact Steve Ingalsbe. <br /> Structural <br /> �1. Previous comment`. The deteriorated roof structure supports do not appear adequate to <br /> support dead and live loads for snow, seismic, and wind, per IPMC section 304.4 and <br /> IBC sections <br /> .�a. Please submit the upper roof framing plans and calculations for the penthouse <br /> roof enclosure and floor framing. Either a structural roof design should be <br /> submitted per (b) below; or, indicate demolition and removal of the enclosed <br /> penthouse roof structure that was built without permits. <br /> J O� b. Please provide stamped engineering calculations and drawings by a Washington <br /> State Licensed engineer showing the roof framing, and enough details to indicate <br /> that the supports, attachments and design of the penthouse roof structure are <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8882 <br />
The URL can be used to link to this page
Your browser does not support the video tag.