• 1892 <br /> � PUBL/C �f/O/�//C5' EVEr�z-r �'i��Depar�me�� <br /> � <br /> • A worksheet showing compliance with RCW 64.55 for the building enclosure is required <br /> with the permit application for work done to the building enclosure. <br /> FIRE DEPARTMENT CORRECTIONS (NO PERMIT� REQUIRED) <br /> Fire hazards listed on the following pages must be removed or abated. <br /> la IFC 315.3 Storaqe in Buildings <br /> Comments: Storage of materials in buildings shall be orderly and stacks shall be <br /> stable. Storage of combustible materials shall be separated from heaters <br /> or heating devices by distance or shielding so that ignition cannot occur. <br /> Location: Internal storage areas. <br /> 2. IFC 605.1 Abatement of Electrical Hazards <br /> Comments: Electrical hazards shall be abated. Hazardous electrical conditions in <br /> permanent wiring shall be brought to the attention of the responsible <br /> code official. Electrical wiring, devices, appliances and other equipment <br /> that is modified or damaged and constitutes an electrical shock or fire <br /> hazard shall not be used. <br /> LQcation: Throughout building. <br /> .�e ��L ���e� ��:��;�c�ca�c� �;orc�� <br /> Commeni:s: i he electrical extension cord(s) rnust be removed. Extension cords shall <br /> not be used as a substitute for permanent wiring and shall be used only <br /> with portable appliances. The ampacity of extension cords shall not be <br /> less than the rated capacity of the portable appliance supplied by the <br /> cord. If additional outlets are necessary, they must be installed in <br /> accordance under permit in accordance with the Electrical Code. <br /> Extension cords and flexible cords shall not be affixed to structures; <br /> extend through walls, ceilings, floors, under doors or floor coverings; or <br /> be subject to environmental or physical damage. <br /> Location: Throughout building. <br /> 4. IFC 703.1 Maintenance <br /> Comments: Repair the required fire separation with a fire-resistive material <br /> equivalent to the surrounding surfaces. <br /> Location: Repair holes in drywall throughout the building. <br /> 5. IFC 807.1 General requirements <br /> Comments: In Group B and M occupancies, fabric partitions suspended from the <br /> ceiling and not supported by the floor shall meet the flame propagation <br /> performance criteria in accordance with Section 807.2 and NFPA 701 or <br /> shall be noncombustible, or shall be removed. <br /> Location: 15t floor art space hallway <br /> _ , <br /> Page 3 of 5 <br />