� ` • • <br /> 8. Specify"gap"at foundation wall to accommodate spray foam insulation. <br /> 9. Detail fire blocking at concealed spaces in below grade walls. <br /> 10. Show how 2x10 floor joists over bonus room are supported over the stair opening. <br /> 11. Provide landing at exterior of single French door in kitchen. The plans show a rockery in <br /> this location. Please clarify. <br /> 12. Adjust stair location to accommodate furred wall at interior of concrete wall. R-21 <br /> insulation required. <br /> 13. Provide cross section of new retaining wall between man cave and crawl space. Show <br /> finished grade in crawl space, framed wall above retaining wall, furred wall on interior <br /> side of retaining wall. Detail fire blocking. <br /> 14. Specify rebar diameter, spacing and depth of embedment at all locations. <br /> 15. Show how bonus room addition meets requirements for insulation at slab-on-grad per <br /> Washington State Energy Code Table 6-1. <br /> 16. Show how foundation at existing family room is tied into new retaining wall at north side <br /> of remodel. <br /> 17. Specify reinforcing steel in all new foundation walls. Specify anchor bolt size and <br /> spacing for all new and replaced foundations. <br /> 18. Provide smoke alarms per Section R314 and carbon monoxide alarms per Section R305 <br /> International Residential Code. Show on plans. <br /> 19. Specify handrail requirements per Section R311.7.7 IRC. <br /> 20. All wood in contact with concrete to be pressure treated. <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> ��'�� /`����,-__- <br /> ]eff Heilman <br /> Development Technician <br /> 425-257-8976 <br /> Email: iheilman@ci.everett.wa.us <br /> S•\7('nmmnn\f lariral\1Hailman\('1 J(19-flfl4('3f17 R()th PI SWl rinr <br />
The URL can be used to link to this page
Your browser does not support the video tag.