My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
931 BROADWAY TEUTSCH STUDENT HOUSING 2018-03-07
>
Address Records
>
BROADWAY
>
931
>
TEUTSCH STUDENT HOUSING
>
931 BROADWAY TEUTSCH STUDENT HOUSING 2018-03-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2018 10:00:50 AM
Creation date
1/17/2018 4:21:42 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
931
Tenant Name
TEUTSCH STUDENT HOUSING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � <br /> tneasures at thc n�rth end oFthe allcy, if doing so wot�ld be feasiblc without causin� �,rosion �r Iloodiii�;. <br /> If no other feasible disposal option is found to exist, the runoff from the alley may enter the storm <br /> drainage system of the new project, but only if the City is granted a hold-harmless agreement from the <br /> applicant for potential damage to the private system from the alley runoff. <br /> 12. Stormwater from the project shall be kept separate from the site's sanitary sewage and shall be connected <br /> to the combined sewer main in Broadway in a manner approved by the City. For the drainage connection <br /> to the combined sewer, provide a structure that can be re-connected to the future separated storn7 main. <br /> 13. Current plans indicate that one of the existing sewer stubs is to be reused as a stormwater discharge point. <br /> Please connect to either of the existing stormwater systems at the entrance to the college across <br /> Broadway to the NW of the property or across l Oth St to the SF of the property. <br /> 14. A cleanout is required at the property line per City of Everett Standard Drawing 602 for each side sewer <br /> and storm service drain. <br /> 15. Provide a manhole at the connection to the sewer main. <br /> 16. It is highly advisable that the existing 6-inch concrete side sewer be replaced with a new PVC side sewer. <br /> The c�ondition �f the eYistin� side sewer in thc ri�ht-�f-�va�r is �i�estiotlablc �F�r fl1e l�n�revitv �f t��e <br /> proposed project with high usage at peak hours. Additionally, if trees are going to be planted without a <br /> concrete structural box, then there are chances of roots entering at the connection point between new and <br /> existing side sewers as well as a high likelihood of damage to the side sewer. The new PVC sanitary side <br /> sewei- can be located where needed along the l3roadway combined sewer main or can be connected at the <br /> same location as the existing side sewer to be replaced. <br /> 17. Frontage/roadway/alley/pedestrian/bicycle improvements shall be provided as needed. Frontage <br /> improvements shall extend across the alley driveway. <br /> 18. Any broken or damaged sidewalk/public right-of-way shall be repaired/replaced in accordance with <br /> current City of Everett Standards and per the City Public Works Inspector. <br /> 19. All roadways must meet City of Everett Standards. <br /> 20. All sidewalks and driveways must be ADA compliant. Provide ADA-approved wheel chair ramps at all <br /> crosswalks. <br /> 21. All traffic control markings and devices on driveways within 50' of the right-of-way shall be MUTCD <br /> compliant. <br /> 22. A stop sign must be added to each driveway access point. <br /> 23. Parking layout must be consistent with current City of Everett Standards, including but not limited to <br /> parking aisle widths and parking stall dimensions. <br /> 24. Provide a new street light approximately mid-block along 101h Street between North�3roadway and <br /> Broadway. <br /> b��� l� <br /> FINAL MDNS SEPA#16-008 � / �� <br /> oC <br />
The URL can be used to link to this page
Your browser does not support the video tag.