My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
931 BROADWAY TEUTSCH STUDENT HOUSING 2018-03-07
>
Address Records
>
BROADWAY
>
931
>
TEUTSCH STUDENT HOUSING
>
931 BROADWAY TEUTSCH STUDENT HOUSING 2018-03-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2018 10:00:50 AM
Creation date
1/17/2018 4:21:42 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
931
Tenant Name
TEUTSCH STUDENT HOUSING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> � <br /> PUBL/C WORKS <br /> .� �- <br /> ,y. On Sheet CO3, the alley is shown with a different hatch pattern than all other <br /> proposed asphalt on the site plan. Is this alley paving to remain existing or will it <br /> be proposed re-paving with the development? If proposed, please update the <br /> hatch pattern to inatch all other asphalt paving. If existing, please show the <br /> trenching extents for the proposed usidergrotmd power. <br /> vi. On Sheet C04, the proposed curb ramp technically meets maximum allowable <br /> slopes, however is a very tight tolerance for contractors to meet in the field. If the <br /> constructed ramp exceeds, it will have to bc redone. Additionally, as designed, <br /> there are very steep (and in my opinion unnecessary) slopes behind the curb ramp <br /> as it transitions into the landscaping. I would highly recommend making the <br /> ramp slopes a bit shallower to create a nice landing and gentle transition into the <br /> landscaping. This will help with safety and maintenance in this area. <br /> vii. On Sheet C04, a cross walk is required north-south across 10`�' St. Stop Bar and <br /> Cross walk striping and location shall meet standard design requirements. <br /> viii. On Sheet C06, where is the mechanical room located within the building? Please <br /> show this on the site plan (dashed approximate lines are acceptable with a label). <br /> The RPBA on the domestic service line and the DCDA on the fire service line <br /> can be located within fhe mechanical room if the distance from the water service <br /> connections to the main and the mechanical room does not exceed 70ft. This <br /> distance is the maximum allowable piping length (total of both outside of the <br /> building and plumbitig inside of the buildiu� fi�otu main to ineclianical rooin) iii <br /> order for the RPBA and DCDA to be inside the mechanical room. Otherwise, <br /> tlic�� ii�ust hc I��catcd ��utsicic c�[�tllc buil�ji��b in �� ��aul�. <br /> ix. On Sheet C06, if the 4" fire service is proposed as a dedicated fire service, then a <br /> DCDA in the vault is sufficient (instead of compound meter). <br /> x. On Sheet C06, please make a note on the plans (near key note 3) that City of <br /> Everett crews will do the tap at the main and will install the 2" domestic meter. <br /> An RPBA is required at the premiss downstream of the meter. If placing RPBA <br /> inside building's mechanical room, please make a note on the plans calling this <br /> out. <br /> 2. The comments below were generated from this project's Stormwater Reviewer. If you have any <br /> questions regarding these comments, please contact Jane Zimmerman with the City of Everett <br /> Public Warks Department (425-257-8885 or JZiminerman(�a,everettwa.gov). <br /> a. Pump related: <br /> i. The pump design, selection, and specification selection information must be <br /> provided in both the report and on the plans for the initial installation. If/when <br /> one of the pumps fails in the fiiture, there must be enough information given to <br /> allow the City's inspector and the site owner to identify a suitable replacement <br /> pump. <br /> ii. Pump calculations are required showing the determination of the total dynamic <br /> head. In addition, the system curve (the pump's total dynamic head versus the <br /> flo��� ratc in ihc systcil�) sh��uld bc plottcd on t11c scicctcd pump's characicristic <br /> curve in order to show the pump's operating point. <br /> Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.