Laserfiche WebLink
LANDSCAPE NOTES <br /> • <br /> , SITE PREPARATION POLYING <br /> POLYETHYLENE TREE <br /> TIE(ALLOW SOME <br /> 1.INSTALL TEMPORARY EROSION AND SEDIMENT CONTROLS IN CONFORMANCE WITH THE A.,+o SLACK) <br /> PROJECTS STORM WATER POLLUTION PREVENTION PLAN. 1 <br /> `1' („ (2)2'x2'xB`TREE <br /> 2.A PRECONSTRUCTION MEETING BETWEEN THE OWNER'S REPRESENTATIVE AND ¢SI, STAKES LOCATED <br /> CONTRACTOR SHALL OCCUR PRIOR TO CONSTRUCTION. ` OUTSIDE <br /> EQUIDISTANTLY <br /> �;F OUTSIDE ROOTBALL <br /> 3.ALL EXISTING UNDERGROUND POWER LINES SHALL BE LOCATED AND FLAGGED BY s ' <br /> CONTRACTOR PRIOR TO ANY EARTH WORK IN THE PLANTING AREAS. ,fi�n ROOT CROWN 2,4''u ".' I ABOVE FINISH GRADE <br /> 4.THE CONTRACTOR SHALL INSTALL LIMIT OF WORK(HIGH VISIBILITY FENCING)ALONG j 3'BARK MULCH RING, <br /> PERIMETERS THAT BORDER ANY AREAS OF VEGETATION NOT TO BE DISTURBED. x finy HOLD BACK 3'FROM <br /> O m ,tf r. MAIN STEM <br /> 5.CLEAR AND GRUB EXISTING VEGETATION IN AREAS TO BE PLANTED AS SHOWN ON THE i m <br /> PLAN. N F..., SHRUB OR <br /> "A- A '•^ •" GROUNDCOVER <br /> 6.GRUB TOA DEPTH SUFFICIENT TO REMOVE ALL LARGE ROOTS,ROOT CROWNS,AND t/•• I'r <br /> OTHER VEGETATIVE MATERIAL.ALL VEGETATIVE DEBRIS SHALL BE REMOVED FROM SITE. ) 77,,,UIU -I��ill ��L. <br /> //, "� /sem `---�FINISH GRADE <br /> 7.PLANTING BEDS SHALL RECEIVE TOPSOIL CONSISTING OF 50%SANDY LOAM AND 50% z i`1, TOPSOIL <br /> COMPOST BY VOLUME PASSING A 3/"SCREEN(CEDAR GROVE TWO-WAY OR APPROVED 2 1n' <br /> EQUAL).PLACE TOPSOIL AND COMPACTED BETWEEN 75%AND 80%.REMOVE ALL ROCKS AND _. FERTILIZER PER <br /> STICKS GREATER THAN 2"(IN ANY DIMENSION)AND CONSTRUCTION DEBRIS(E.G.,CONCRETE 1, NOTES <br /> SLURRY)PRIOR TO PLACEMENT.OWNER'S REPRESENTATIVE SHALL APPROVE SOIL <br /> MIN.2 X EXISTING <br /> PREPARATION PRIOR TO PLANT INSTALLATION. - <br /> ROOTBALL SUBGRADE <br /> 8.RAKE PLANTING BED AREAS TO A SMOOTH,UNIFORM SURFACE PLANE 4"BELOW <br /> ADJACENT WALKS OR BEDS FOR BARK MULCH AND 2"BELOW ADJACENT WALKS FOR LAWN <br /> AREAS. TREE PLANTING <br /> PLANTING GENERAL NOT TO SCALE <br /> 1.ALL PLANT MATERIALS SHALL CONFORM TO THE AMERICAN NURSERY LANDSCAPE <br /> ASSOCIATION(ANCA)STANDARDS FOR NURSERY STOCK(ANSI Z 60.1-2004)FOR GRADE AND <br /> SIZE UNLESS NOTED OTHERWISE ON PLAN. <br /> 2.SUBSTITUTIONS SHALL BE AUTHORIZED BY THE OWNER'S REPRESENTATIVE. IF PLANTS <br /> ARE NOT AVAILABLE,CONTACT THE OWNER'S REPRESENTATIVE FOR APPROVED SOURCES <br /> OR SUBSTITUTIONS. ROOT CROWN 7'-2'ABOVE <br /> 3.PLANT MATERIALS SHALL BE INSPECTED AT THE NURSERY OR PROJECT SITE BY THE ;.. u F.-,% AMENDED SOIL GRADE <br /> OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION.INSPECTION MAY INCLUDE,BUT NOT •_ o 0..:A, 3'BARK MULCH RING,HOLD BACK <br /> LIMITED TO,APPROPRIATE NUMBER OF TRUNKS FOR THE SPECIES;CROWN;HEALTH AND �`k +' . 2'-3'AWAY FROM MAIN <br /> VIGOR;ROOT STRUCTURE AND VIGOR. >-`- ;� }I STEM <br /> "�' GROUNDCOVERI <br /> 4.IN THE EVENT OF VARIATION BETWEEN THE PLANT SCHEDULE AND THE NUMBER OF7. BARK MULCH <br /> PLANTS SHOWN ON THE PLANS,THE PLANS SHALL CONTROL. .a j FINISH GRADE <br /> 5.THE CONTRACTOR SHALL VERIFY THAT PLANT INSTALLATION CONDITIONS ARE SUITABLE d'. <br /> WITHIN PLANTING AREAS.THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE / rII'' <br /> OF ANY UNSATISFACTORY CONDITIONS AND ADDRESS THEM PRIOR TO START OF PLANTING. I//�i TOPSOIL <br /> BEGINNING OF WORK CONSTITUTES VERIFICATION THAT CONDITIONS ARE SATISFACTORY. ' j FERTILIZER PER <br /> _1 PLANTING NOTES <br /> 6.THE CONTRACTOR SHALL PROVIDE LANDSCAPE AS-BUILT DRAWING MARKUPS LEGIBLY MIN.2 X EXISTING SUBGRADE <br /> MARKED TO RECORD ACTUAL INSTALLATION.DRAWINGS SHALL INDICATE PLANT LOCATIONS ROOT BALL 1 <br /> REFERENCED TO PROJECT IMPROVEMENTS.IDENTIFY FIELD CHANGES AUTHORIZED BY <br /> OWNER'S REPRESENTATIVE.AS-BUILT DRAWING SHALL BE SUBMITTED TO OWNER'S SHRUB PLANTING <br /> REPRESENTATIVE AT SUBSTANTIAL COMPLETION WALK THROUGH. NOT TO SCALE <br /> PLANTING INSTALLATION <br /> 1.OWNER'S REPRESENTATIVE SHALL APPROVE THE METHOD AND LAYOUT OF PLANTING IN <br /> THE PLANTING AREAS PRIOR TO PLANT INSTALLATION.PLANTS INSTALLED NEAR UTILITY <br /> VAULTS AND BOXES SHALL BE FIELD-ADJUSTED(AS NECESSARY). <br /> GROUNDCOVER PLANTS <br /> $INSTALL ALL TREES AND SHRUBS IN THE PLANTING AREAS PER THE PLANS AND AS y ,, BARK MULCH-DEPTH AS SPECIFIED <br /> SHOWN IN THE PLANTING DETAILS- •-llt �,,"'� fits. 3-,_ <br /> all ll I <br /> ';Ti ADD GRANULAR 14-MONTH SLOW RELEASE,HIGH NITROGEN FERTILIZER(OSMOCOTE <br /> 14-14-14 OR APPROVED EQUAL)TO PLANTING PITS PRIOR TO BACKFILL.APPLY PER - - _� FINISH GRADE <br /> MANUFACTURER'S WRITTEN INSTRUCTIONS. PREPARED BED-DEPTH As <br /> - - SPECIFIED <br /> q APPLY PRE-EMERGENT HERBICIDE(SNAPSHOT OR APPROVED EQUAL)TO ALL PLANTING <br /> BEDS PER MANUFACTURER'S WRITTEN INSTRUCTIONS FOR WEED CONTROL PRIOR TO BARK NOTE: <br /> MULCH APPLICATION. LOCATE PLANTS SPACED EQUAL DISTANCE(DI <br /> - FROM EACH OTHER AS SHOWN. <br /> P3DRESS ALL PLANTING AREAS UNIFORMLY WITH 3"OF MEDIUM BARK MULCH AS SHOWN ON D=AS NOTED ON PLANTING SCHEDULE. <br /> THE PLAN.PLACE TOP OF BARK MULCH 1"BELOW ADJACENT WALKS OR CURBS.SUBMIT o PAl"A 5MtAX..W.L at axra <br /> SAMPLE TO OWNER'S REPRESENTATIVE FOR APPROVAL BARK MULCH SHALL BE DERIVED DI <br /> FROM DOUGLAS FIR,PINE,OR HEMLOCK,MEETING THE FOLLOWING LOOSE VOLUME =! • • • • • • <br /> GRADATION. <br /> a 0 <br /> SCREEN PERCENT PASSING • • • • • <br /> c <br /> MIK MAX. <br /> 2" 95 IOD <br /> • • • • • • <br /> NO.4 O 30 <br /> I ___ GROUNDCOVER PLANTING <br /> FINISH GRADE NOT TO SCALE <br /> IIIIIIIIIIIIIIIIIWIIIIIIIIIIiM 3'BARK MULCH '=-1ii r' <br /> „•-c,,. PLACE 9'TOPSOIL U (�, i.:,,.,:i U ISI <br /> f'Jlar'.- -brie ' J. _J 3"SCARIFY SUBGRADE <br /> 1OCT 022017 <br /> EXISTING SUBGRADE <br /> CITY OF EVERC- <br /> PLANTING BED PREPARATION CITY OF EVERETT <br /> NOT TO SCALE Permit ServirP^., <br /> REVIEWED FOR PERMIT <br />