, <br /> • • <br /> Underground Sprinkler line certified"U" installers. For further information,contact the State Fire <br /> Marshal's Office at(360)596-3900 or contact the Everett Fire Department at(425)257-8124.) All <br /> such tests shall be witnessed by a Fire Department inspector. Call (425)257-8124 or(425)257-8120 <br /> to make an appointment for inspection. <br /> Contractors' materials and test certificates shall be submitted to the Everett Fire Department prior <br /> to issuance of any Certificates of Occupancy. <br /> Call (425)257-8124 for more information. <br /> 17.If required per design,standpipe systems shall comply with NFPA 14. Standpipe systems shall be <br /> installed throughout buildings where the floor level of the highest story is located more than 30 feet <br /> above the lowest level of the fire department vehicle access,or where the floor level of the lowest <br /> story is located more than 30 feet below the highest level of fire department vehicle access. <br /> A standpipe hookup(1)VA"fire hose connection shall be placed at the bottom of the hatch access <br /> to the roof. <br /> 18. Per Boeing standards-Floors and sub-floors at or above grade in buildings(other than parking <br /> garages) shall be marked with numbers,in ascending order,beginning with the number"1" (for the <br /> ground floor or first floor),then "2", "3",etc. Letters shall be used only to designate specific areas <br /> as detailed below. <br /> Floors below grade in buildings(other than parking garages)shall be marked with the letter"B" <br /> (when there is only one floor below grade). When there is more than one floor below grade,they <br /> shall be marked with the letter"B"followed by numbers, in descending order, beginning with the <br /> number"1" (for the floor immediately below the ground floor or first floor),then "r, "3",etc. <br /> Example—"B1", "B2","B3", in descending order. <br /> Mezzanines shall be marked with the letter"M". When there is more than one mezzanine,they <br /> shall be marked with the letter"M"followed by numbers, in ascending order. Example—"Ml", <br /> "M2", etc. <br /> Parking garages shall use the letter"P"to designate floors. • <br /> When there is only one parking level at or above grade,it shall be marked with the letter"P". When <br /> there is more than one parking level at or above grade,they shall be marked with the letter"P" <br /> followed by numbers, in ascending order. Example—"P1""P2",etc. <br /> When there is only one parking level below grade, it shall be marked"P01". When there is more <br /> than one parking level below grade,they shall be marked with the letter"P"followed by numbers, <br /> in descending order. Example—"P01", "P02",etc. <br /> Large parking structures may use letters to designate columns for ease of locating automobiles. <br /> Example—"Floor P3,Column E". <br />