CITY OF EVERETT SPECIAL PROVISIONS <br /> 111 7-09.3(25) Mechanical Joint Restraining Devices <br /> (******) <br /> Restrain joints at bends, tees, dead ends and connections to existing water mains as <br /> shown on the Plans using mechanical joint restraining devices. <br /> Install joint restraint system in accordance with the manufacturer's recommendations. <br /> ' 7-09.4 Measurement <br /> Delete all paragraphs of 7-09.4 and substitute the following: <br /> Bid items of Work completed pursuant to the Contract Documents will be measured as <br /> described in Division B - Bid Item Descriptions of these Special Provisions and <br /> Section 1-09 MEASUREMENT AND PAYMENT of the Standard Specifications. <br /> 7-09.5 Payment <br /> Delete all paragraphs of 7-09.5 and substitute the following: <br /> Payment for bid items of Work completed pursuant to the Contract Documents will be <br /> as described in Division B - Bid Item Descriptions of these Special Provisions and <br /> Section 1-09 MEASUREMENT AND PAYMENT of the Standard Specifications. <br /> 7-12 VALVES FOR WATER MAINS <br /> 7-12.1 Description <br /> Supplement 7-12.1 as follows: <br /> ' 7-12.1(1) Submittals <br /> (******) <br /> Provide Type 2 Working Drawings for all materials and Standard Plans. <br /> ' 7-12.2 Materials <br /> Delete the first paragraph in 7-12.2 and substitute the following <br /> Provide materials meeting the requirements of the following: <br /> ' Gate Valves (2-inches to 12-inches) <br /> 9-30.3(1) Special Provisions <br /> Butterfly Valves 9 30.3(3) Special Provisions <br /> Valve Boxes 9-30.3(4) Special Provisions <br /> Valve Stem Extensions <br /> 9-30.3(6) Special Provisions <br /> Combination Air ReleaseNacuum Valve <br /> 9-30.3(7) Special Provisions <br /> Tapping Sleeve and Valve 9-30.3(8) Special Provisions <br /> Assembly <br /> 7-12.3 Construction Requirements <br /> Supplement 7-12.3 by adding the following: <br /> Install valve box centered on the operator nut. <br /> Provide 3-inch thick x 2-feet x 2-feet HMA concrete pad around valve boxes located <br /> within gravel surface. <br /> Provide one valve stem extension, minimum 12-inch length, in accordance with COE <br /> Standard Drawing No. 505 when the top of the valve operating nut is more than three <br /> feet below finished grade. <br /> ' Provide equipment, labor, tools, materials and miscellaneous parts to perform <br /> pavement sawing, pavement removal, excavations, shoring, traffic control and other <br /> Work required to prepare the site for City Utility Department personnel to install the <br /> City supplied tapping sleeve and valve assembly. <br /> Notify City Utility Department a minimum of five business days for each tap being <br /> made. The Utility Department will determine the date and time to make each tap. <br /> Water Main Replacement"Q" Division 7-STORM,SEWER,WATER February 9, 2018 <br /> -Evergreen Way Rebid <br /> WO No.-UP3612 SP-157 <br />