Laserfiche WebLink
1 1 <br /> 2 "Loop Detector Lead-In Cable", per linear foot. <br /> i 3 <br /> 4 The unit contract price shall be full pay for furnishing and installing each loop detector <br /> 5 lead-in cable in existing conduits between the traffic signal control cabinet and loop <br /> 1 6 splice point, including all and all other Work necessary terminate loop lead-in cable at <br /> 7 either end. <br /> 8 <br /> I 9 <br /> 10 No payment shall be made for any detector lead-in cable that is not spliced and fully <br /> operational, including any testing required to make the loop operational. <br /> 11 <br /> I 12 "Conduit Pipe 2 In. Diam.", per linear foot. <br /> 13 <br /> 14 The unit contract price shall be full pay as described in this Section for furnishing and <br /> I 15 <br /> 16 installing each conduit stub-out where shown in the Plans, including furnishing all <br /> conduit, elbows, bends, and fittings for placing the pipe in accordance with the above <br /> 17 provisions, including all excavation or jacking required, backfilling of any voids around <br /> 18 stub out, pits, or trenches; bedding of the pipe, chipping of pavement, and all other Work <br /> 19 necessary for the construction of the conduit stub-out. <br /> 20 <br /> 21 "Replace Junction Box" per each. <br /> I 22 <br /> 23 The unit contract price shall be full pay for all costs associated with replacing junction <br /> 24 boxes including excavation and installation of junction box load bearing rings, <br /> I 25 intermediate and final adjustment to grade, saw cutting or grouting of existing vaults, or <br /> 26 other work to install the junction box in the sidewalk. <br /> 27 <br /> I 28 CNH 8-22.DOCX <br /> 29 8-22 PAVEMENT MARKING <br /> 30 <br /> I 31 8-22.2 Materials <br /> 32 <br /> 33 Section 8-22.2 is supplemented with the following: <br /> ,y. <br /> I 34 <br /> 35 (---) <br /> 36 All plastic marking shall be Type D. <br /> 37 <br /> I38 8-22.3 Construction Requirements <br /> 39 <br /> 40 Section 8-22.3 is supplemented with the following: <br /> 1 41 <br /> 42 (******) <br /> I 43 Pavement markings shall be installed in accordance with Section 8-22.3 of the Standard <br /> 44 Specifications with the following modifications: <br /> 45 <br /> 1 46 1. All Stop Line shall be 24" wide Type D extruded plastic flat line. Spray Type D is <br /> 47 not allowed. <br /> I 48 2. All Crosswalk Line shall be solid white lines, 24" wide, installed in accordance <br /> 49 with City of Everett Standard Drawing No. 721 and shall be Type D extruded <br /> 50 plastic flat line. Spray Type D is not allowed. <br /> I <br /> HOT MIX ASPHALT OVERLAY-2018 PAGE 51 OF 57 March 6, 2018 <br /> I WORK ORDER#3667 <br /> SPECIAL PROVISIONS <br />