Laserfiche WebLink
r � <br /> 2813 Rockefeller Ave. Everett, WA 98201• ph:425.317.8017 •fax:425.317.8489 <br /> City of Everett <br /> Public Services Department <br /> 3200 Cedar Street <br /> Everett, WA 98201 <br /> 1.27.2017 <br /> Re: PLAN CHECK NUMBER: C1609-027 <br /> PROJECT NAME: Sawiris Residence <br /> PROJECT ADDRESS: 2107 Grand Ave. <br /> Building Division <br /> 1. The proposed Bedroom does not meet the minimum area for habitable space per IRC section <br /> R304. <br /> Re�;��iise: 13eclroo;�� squar�� fiootage has been revisecl on proposed floor plan to be 70 sy. ft. on <br /> � �.�I��n note 3 in sheet A-2.1 per IRC section R304. <br /> 2. Specify the U-Value for all new fenestration on the construction drawings (you have chosen to use <br /> option 1a for your energy credits, notations need to reflect those values on the plans). <br /> - � ���. � � �� � �_� , � �,.- ��, � ���-� � �,� - <br /> �; Information. Additionally, Added U values on the window schedule sheet A-2.1 for the new <br /> �vin;iow (LI-.7_8) to reflect the val�_i�s pc�r WSEC Tahle 406.2, option 1a. <br /> 3. Specify the pitch of the roof at the proposed laundry room addition. 3-tab composition roofing <br /> requires a minimum pitch of two units vertical in 12 units horizontal per section R905.2.2 IRC, the <br /> plans show%z unit vertical in 12 units horizontal. <br /> f;,_ � ,.. ' � � �� ���_ � � � � ��� i i <br /> ' (VIF) of the existing roof over the dining room. Changes made to�proposed roof plan on sheet A- <br /> 2.? to r�fl��ct this <br /> 4. Provide R-10 rigid insulation at all headers in bearing exterior walls per Table R402.1.1 of the <br /> WSEC. Show on plans. <br /> - �, i _ , ,_ i � �� __ � <br /> ' �i <br /> 5. Section AA and Section CC on sheet A-3.2 show similar construction in the Dining Room and the <br /> Laundry Room, while Wall Section 1 on Sheet A-3.3 shows something completely different in the <br /> Laundry Room.The section drawing at the laundry room shows the roof of the addition supported <br /> by the existing partial height exterior wall at the house. Please clarify the actual construction at <br /> this location. Provide ledger detail if applicable (section and elevation of ledger) showing all <br /> connectors. <br /> _.i,:-: �',�ii�. - ;�_i�i�- �,, ��cCCG�i_. � �.li_;:�. � � , , ,� ,;1. ii ���il , _��,�n :1o�l <br /> sheet A-3.3 has been removed. We have revised the foundation and roof framing at the addition <br /> per structural engineer's revisions. Attached are structural details, sheet S-1, for the connections <br /> at the foundation and roof. Clarification of actual construction on Section AA has been done <br /> �j'� 3 ������ through notes and revisions per structural. <br /> Y�� �P���s �� G�UNG ��,s>r c4u.� 01�. N� �f✓/�/��p,,,' 1 � Page <br /> �t���Sv� � 'lP0 (.�(OC�R 5�.}ou��l. <br /> �� <br />