Laserfiche WebLink
EVERETT DOWNTOWN STREETSCAPE IMPROVEMENT — RUCKER AVE. <br /> Agreement with Perteet Inc. July 16, 2018 <br /> • Commercial meter vaults and other below grade structures 4'x4' and <br /> larger shall be shown to scale and bottom of vault elevation noted, if <br /> possible. <br /> • Water line appurtenance symbols shall be per City of Everett standards <br /> and shown to a reasonable scale on plans. <br /> • All line work will be in model space. Drawing units shall be U.S. Survey <br /> Feet. <br /> • City of Everett CAD standards for layers and symbols will be used <br /> 2.3 QA/QC Of Deliverables: <br /> An internal Consultant quality assurance/quality control review of deliverables will <br /> be conducted, as well as confirmation that comments received have been <br /> addressed. A record of comments received will be maintained. Response to each <br /> comment received will be tracked to confirm that they have been addressed <br /> Assumptions: <br /> © Consultant personnel are not certified for confined space entry; thus all storm <br /> drainage pipe inverts within control structures will be measured from the rim <br /> of catch basins and manholes. <br /> • This Scope of Services does not include the referencing of and preparation of <br /> Department of Natural Resources (DNR) monument destruction/disturbance <br /> forms. <br /> • Requested areas for survey beyond the agreed upon mapping limits detailed <br /> in this work element, or areas previously surveyed during the previous phase <br /> of the project, are not a part of this scope and should be considered extra <br /> work. <br /> Page 6 1 03 Scope of Services <br />