Laserfiche WebLink
�, A landscape strip <br />north and south <br />landscaping. <br />a minimum of five feet wide must be provided along the <br />property lines. This area shall be planted with Type III <br />� South p operty ne whe e the property abuta the Rt3b one. VTh� area shall <br />be planted with Type I landscaping. <br />d. A minimum of 752.5 square feet of landscaping shall be provided in the <br />interior of the parking lot for the 43 parking stalls. Landscaping must be <br />provided per Section 35.080E of the Zoning Code. <br />e, Prior to issuance of any permits, landscaping plans must bc reviewed and <br />approved by the Plamung Department per Section 35.100 of the Zoning <br />Code. The landscaping plan must show location and dimensions of <br />required vegetated swales, wetponds, detention ponds, rockeries and <br />retaining wa1�s, and grading at 2 foot intervals. Irrigation systems must be <br />provided in all laddscaped areas per Section 35.130 of the Zoning Code. A <br />2 year maintenance assurance device must be provided for the landscaping <br />per Section 35. ] 30B of the Zoning Code. <br />18. Based upon 3,100 square feet of Type V-N, unsprinklered construction, the fire <br />flow requirement is 1,500 GPM. <br />19. One available hydrant must be installed. A fire hydrant is required within 200 <br />driving feet, but not closer than 50 feet, of every structure. The location of the <br />hydrant must be approved by the Fire Ma��shal. <br />20 <br />21 <br />22. <br />23. <br />M approved automatic fire detection system must be in compliance with Article <br />87 of the Uniform Fire Code. Plans for such system must be submitted to the Fire <br />Marshal for review and approval prior to installation. Submittal shall include cut <br />sheets of all equipment intended for us�. Appropriate trip tests, witnessed by a <br />Fire Department mspector, must be performed pnor to final acceptance of the <br />system. Fire alarm system must be installed under permit.of the City of Everett <br />Building Department. Electrical inspections and apnroval are required prior to <br />calling for acceptance tests. Call 259-8810 for pe�mt infortnation. <br />wit in 75' feet t avtel distanece on each floor of U portions of ea h build ngr during <br />construction and prior to occupa:icy. <br />The premises m�st be clearly identified by address at the street entry. Each <br />building must be clearly identified so as to be visible and legible from ihe access <br />road. Each suife must be clearly identified so as to be visible and legible from the <br />access road. <br />When access to or within a structure or an area is unduly difficult because of <br />secured openings or where immediate access is necessary for life saving or fire- <br />fishtirg purposes, the Fire Department may recommend or require a key box to be <br />installed m an accessible location. A rapid entry system may aJso be desiraUle in <br />order to avoid unnecessary damage while making entry to any building during an <br />emergency situation. <br />Please call 259-8726 for further information. <br />