My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7600 EVERGREEN WAY EVERETT CLINIC 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
7600
>
EVERETT CLINIC
>
7600 EVERGREEN WAY EVERETT CLINIC 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2018 3:28:06 PM
Creation date
10/17/2018 3:17:29 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7600
Tenant Name
EVERETT CLINIC
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( <br />2. The area calculations for the existing building floor area changed in the <br />code analysis from 30,597 square feet to 29,967 square feet from <br />permit B1103-035 to permit B1107-022. Snohomish County <br />Assessor's ofFice indicates 30,384 square feet. Please clarify. <br />Occupancy <br />1. A table with a summary of square foot area, occupant load, and <br />t <br />occupant type should be shown for each space on the drawings o <br />determine the total occupant load of the tenant space. <br />a. This table should include the documentation that the accessory <br />occupancy of assembly does not exceed 10% of the floor area of <br />the building area on this story, per IBC section 508.2.1. <br />b. The current floor area identified as assembly use exceeds the <br />10% threshold for the building area of 30,384 square feet. <br />c. The current gross building occupant load will increase based on <br />the cumulative occupant loads deterrnined for assembly spaces. <br />d. The cumulative individual space occupant load should total the <br />gross building occupant load. Currently there is a discrepancy <br />of 138 occupants between these two calculations. <br />2. Sheet A01 identifies several rooms as <br />the use and occupant load appear to b <br />those rooms, which would make these <br />IBC section 303.1, exception 1. <br />being assembly occupancy, <br />e lower than 50 on many of <br />rooms business occupancy, <br />but <br />per <br />3. Each room with assembly occupancy should indicate the location of the <br />sign for the posted occupant load on the drawings, per IBC section <br />1004.3. <br />Construction <br />1. Please explain the use of the lab room 177 to determine whether the <br />requirements for IMC section 510.1 apply to this room, or if another <br />type of source specific exhaust is required. <br />Automatic fire detection should be identified on the drawings as being <br />included in the scope of this project. <br />3. Roof access, shown as new on this permit =ubmittal from Room 182, <br />should be detailed on the drawings to meet requirements of IMC <br />section 306.5 and IBC section 1009.13.2. <br />4. The elevations for doors 138 A and B should be shown on the drawings <br />and should be identified as tempered gla�.ing, if glazed. <br />Egress <br />1. The entry at door'131 A' rFquires more detail to indicate the <br />installation dimensions and profile of: <br />�S <br />
The URL can be used to link to this page
Your browser does not support the video tag.