( <br />2. The area calculations for the existing building floor area changed in the <br />code analysis from 30,597 square feet to 29,967 square feet from <br />permit B1103-035 to permit B1107-022. Snohomish County <br />Assessor's ofFice indicates 30,384 square feet. Please clarify. <br />Occupancy <br />1. A table with a summary of square foot area, occupant load, and <br />t <br />occupant type should be shown for each space on the drawings o <br />determine the total occupant load of the tenant space. <br />a. This table should include the documentation that the accessory <br />occupancy of assembly does not exceed 10% of the floor area of <br />the building area on this story, per IBC section 508.2.1. <br />b. The current floor area identified as assembly use exceeds the <br />10% threshold for the building area of 30,384 square feet. <br />c. The current gross building occupant load will increase based on <br />the cumulative occupant loads deterrnined for assembly spaces. <br />d. The cumulative individual space occupant load should total the <br />gross building occupant load. Currently there is a discrepancy <br />of 138 occupants between these two calculations. <br />2. Sheet A01 identifies several rooms as <br />the use and occupant load appear to b <br />those rooms, which would make these <br />IBC section 303.1, exception 1. <br />being assembly occupancy, <br />e lower than 50 on many of <br />rooms business occupancy, <br />but <br />per <br />3. Each room with assembly occupancy should indicate the location of the <br />sign for the posted occupant load on the drawings, per IBC section <br />1004.3. <br />Construction <br />1. Please explain the use of the lab room 177 to determine whether the <br />requirements for IMC section 510.1 apply to this room, or if another <br />type of source specific exhaust is required. <br />Automatic fire detection should be identified on the drawings as being <br />included in the scope of this project. <br />3. Roof access, shown as new on this permit =ubmittal from Room 182, <br />should be detailed on the drawings to meet requirements of IMC <br />section 306.5 and IBC section 1009.13.2. <br />4. The elevations for doors 138 A and B should be shown on the drawings <br />and should be identified as tempered gla�.ing, if glazed. <br />Egress <br />1. The entry at door'131 A' rFquires more detail to indicate the <br />installation dimensions and profile of: <br />�S <br />