My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9610 EVERGREEN WAY EAGLE CASH EXPRESS 2018-01-02 MF Import
>
Address Records
>
EVERGREEN WAY
>
9610
>
EAGLE CASH EXPRESS
>
9610 EVERGREEN WAY EAGLE CASH EXPRESS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2022 8:24:35 AM
Creation date
10/29/2018 1:35:23 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
9610
Tenant Name
EAGLE CASH EXPRESS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEATTLE ASBESTOS TEST, LLl AIHA LAB ID: 181559 <br />19711 Scriber Like Road, Snite D, Lynnwood, WA e8036 AHERA Inspector Number: 1021898 <br />Phone: (425)673.9850,1'ia:1425) 673-9810 <br />NwN%%wsei0lcasbcstostest.com i stew «Iscattlensbestostest.com Property Location <br />Part of 9610 Evergreen Way, Everett, WA 98204 <br />The method of testing employed are polarized light microscopy, or <br />PLM. For QC purposes, one in every ten samples are analyzed as <br />duplicate and check samples are randomly cross -analyzed by <br />different analysts <br />Table 4 is the test results for the samples taken during the survey. <br />For each sample, it is sub -divided into Iztyers if the sample is <br />separable, and each layer is then prepared into slides and analyzed <br />separately. Each layer is also described to show its color, and nature, <br />so that it provides a check to the homogeneous area classification <br />done on site. Different from the lab report format, which is listed in <br />the appendices, Table 4 also shows the location of each sample, and <br />the material as seen by the inspector on -site. This kind <br />cross-reference enhances degree of certainty to the final report. <br />During this survey, 18 total samples are taken and they are divided <br />into 26 total layers during the laboratory test. <br />Conclusions <br />No asbestos was found during the survey, although extensive <br />sampling was done. <br />Noticeably, the popcorn ceiling in the Storage and Tool room are non <br />ACM, and all the surfacing materials including the orange peel <br />surface and the other wall surfacing materials are all non -detected for <br />asbestos. The checker board patterned tiles are also negative for <br />asbestos. <br />Since the client intent to renovate on the existing building, the exterior <br />walls and roofing were not part of the survey as instructed by the <br />client, hence they are not sampled. <br />Limitations <br />
The URL can be used to link to this page
Your browser does not support the video tag.