Laserfiche WebLink
�. <br />Charmain Slattery, Administrator <br />Sunrise View Convalescent Center <br />CRU N85119-2091-2 <br />June 24, 1985 <br />Page Two <br />front of the water closet. A bar mounted horizontally can be used to <br />push one's self rather than pull. Pushing is much easier to do. <br />For room �204 and similar, an L-shaped grab bar mounted so that the <br />vertical part of the bar is as close to the door casing as possible <br />and the other bar of the "L" is mounted horizontal to the floor at the <br />side of the water closet. WAC 248-14-120(5)�f). <br />2. The grab bar shown at the side of the water closet in elevation B, <br />Sheet A-7 is too short. It must extend 18" beyond the front of the <br />water closet and should extend to within approximately 6" of the wall <br />in back of the water closet. WAC 248-14-120(5)(f) <br />3. There is only one grab bar shown in the shower stali of patients <br />showers. Refer to Unit Plan, Typical - Handicap Unit and Typical Unit <br />Plan on Sheet A-7. Besides the on? grab bar is located over the seat, <br />making the bar useless when seated and also interfering with the <br />seating space. <br />A horizontal grab bar shall be provided on two sides of each shower <br />stall and an L-shaped bar mounted on the shower head side. The <br />horizontal bar shall be mounted 31" to 36" above the floor. None of <br />the bars should interfer with the seating. WAC 248-14-120(6)(e)(iii). <br />4. There needs to be a paper towel dispenser and soap dispensers at all <br />sinks and lavatories that are not in resident rooms and toilets. <br />5. There should be a shelf over or near any wall hung lavatory not built <br />into a vanity. <br />6. The mirror at the lavatory in the serving kitchen needs to be deleted <br />since hair grooming is not permitted in the kitchen. <br />7, There should be a service sink in the janitor's room #110 since there <br />is no other adequately equipped janitor's closet on that floor. <br />8. The specification for the toilet fixture P-1 calls for a solid plastic <br />seat. This is acceptable ror the toilets adjoining resident rooms <br />but toilets in common use areas shall have seats of the open front <br />type. See WAC 248-16-130(3)(d)(ii). <br />STATE FIRE MARSHAL'S REVIEW <br />Pete Anderson 753-1296 <br />1. Fire pr,otection during construction shall be in accordance with <br />Plan Review Information Sheet A1 enclosed (1976 NFPA Standard lul <br />Section 1-5.4). <br />