My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2520 MADISON ST SUNRISE CONVALESCENT CENTER 2018-01-01 MF Import
>
Address Records
>
MADISON ST
>
2520
>
SUNRISE CONVALESCENT CENTER
>
2520 MADISON ST SUNRISE CONVALESCENT CENTER 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2018 1:15:20 PM
Creation date
11/13/2018 7:55:17 AM
Metadata
Fields
Template:
Address Document
Street Name
MADISON ST
Street Number
2520
Tenant Name
SUNRISE CONVALESCENT CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
346
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�. <br />Charmain Slattery, Administrator <br />Sunrise View Convalescent Center <br />CRU N85119-2091-2 <br />June 24, 1985 <br />Page Two <br />front of the water closet. A bar mounted horizontally can be used to <br />push one's self rather than pull. Pushing is much easier to do. <br />For room �204 and similar, an L-shaped grab bar mounted so that the <br />vertical part of the bar is as close to the door casing as possible <br />and the other bar of the "L" is mounted horizontal to the floor at the <br />side of the water closet. WAC 248-14-120(5)�f). <br />2. The grab bar shown at the side of the water closet in elevation B, <br />Sheet A-7 is too short. It must extend 18" beyond the front of the <br />water closet and should extend to within approximately 6" of the wall <br />in back of the water closet. WAC 248-14-120(5)(f) <br />3. There is only one grab bar shown in the shower stali of patients <br />showers. Refer to Unit Plan, Typical - Handicap Unit and Typical Unit <br />Plan on Sheet A-7. Besides the on? grab bar is located over the seat, <br />making the bar useless when seated and also interfering with the <br />seating space. <br />A horizontal grab bar shall be provided on two sides of each shower <br />stall and an L-shaped bar mounted on the shower head side. The <br />horizontal bar shall be mounted 31" to 36" above the floor. None of <br />the bars should interfer with the seating. WAC 248-14-120(6)(e)(iii). <br />4. There needs to be a paper towel dispenser and soap dispensers at all <br />sinks and lavatories that are not in resident rooms and toilets. <br />5. There should be a shelf over or near any wall hung lavatory not built <br />into a vanity. <br />6. The mirror at the lavatory in the serving kitchen needs to be deleted <br />since hair grooming is not permitted in the kitchen. <br />7, There should be a service sink in the janitor's room #110 since there <br />is no other adequately equipped janitor's closet on that floor. <br />8. The specification for the toilet fixture P-1 calls for a solid plastic <br />seat. This is acceptable ror the toilets adjoining resident rooms <br />but toilets in common use areas shall have seats of the open front <br />type. See WAC 248-16-130(3)(d)(ii). <br />STATE FIRE MARSHAL'S REVIEW <br />Pete Anderson 753-1296 <br />1. Fire pr,otection during construction shall be in accordance with <br />Plan Review Information Sheet A1 enclosed (1976 NFPA Standard lul <br />Section 1-5.4). <br />
The URL can be used to link to this page
Your browser does not support the video tag.