My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2727 MAPLE ST EVERETT SELF STORAGE 2018-01-01 MF Import
>
Address Records
>
MAPLE ST
>
2727
>
EVERETT SELF STORAGE
>
2727 MAPLE ST EVERETT SELF STORAGE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2018 2:35:49 PM
Creation date
11/13/2018 2:32:11 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2727
Tenant Name
EVERETT SELF STORAGE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
230
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.�.__ . , . ._ . ... : ..__ .. ._ . .. .. . _ <br /> . . �� <br /> � �' <br /> Plan Check No. B 59621 <br /> September 4, 1998 <br /> Page 2 of 5 <br /> 2. As the administrative portion of the building is less than 25% (in area) of the storage <br /> occupancy, an occupancy separation is not required per Section 302.1. However, if an <br /> occupancy separation is desired, the metal decking for the floor/ceiling assembly should be <br /> shown protected with a spray-on firecoating or equivulent fire-protection. Section 3023 <br /> 3. The calculated occupant load for the warehouse is 16 persons per Table 29-A. One <br /> designated toilet room for each sex should be provided. Section 29023.1 <br /> 4. It should be clarified whether the mechanical rooms contain a cenual heating plant, boiler, or <br /> hot-water supply builer where the largest piece of equipment exceeds 400,000 Btu per hour <br /> input. Section 302.5 <br /> 5. Toilet rooms accessible to the public should be shown to have walls within 2 ft of the &ont <br /> and sides of water closets finished to a height of 4 ft. with a smooth, hazd, non-absorbent <br /> surface. Section 807.1.2 <br /> Construction <br /> 1. The details, construction notes and a section for the two-hour area scparation wall should be <br /> shown on the plans. Section 504.6 <br /> 2. The roof plan should show the location of the area separation wall below with the 10' wide <br /> zone mazked where no openings aze permitted. Section 504.6.4, Exception 3 <br /> 3. The guazdrail on the Ianding for Stair B shown on sheet A6.1 is required to be no less than 42 <br /> inches high. Exception 3 to Section 509.2 <br /> 4. Class I standpipes are required per Table 9-A. The location of the standpipes should be I <br /> shown on the plans. Section 904.53 I <br /> 5. 'fhe pfans should note that penetrations through fire-resistive walls shall be protected by an <br /> approved penetration firestop system installed as tested in accordance with UBC Standazd 7-5 ' <br /> and shall have an F rating of not less than the rating of the wall penetrated. Section 709.63 <br /> 6. Signs should be displayed permanently near or on each required fire door per Section 713.13 <br /> to read as follows: <br /> FIRE DOOR <br /> DO NOT OBSTRUCT <br /> 7. Safety glazing should be shown for the glazing adjacent to the entry door. Section 2406.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.