My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2727 MAPLE ST EVERETT SELF STORAGE 2018-01-01 MF Import
>
Address Records
>
MAPLE ST
>
2727
>
EVERETT SELF STORAGE
>
2727 MAPLE ST EVERETT SELF STORAGE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2018 2:35:49 PM
Creation date
11/13/2018 2:32:11 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2727
Tenant Name
EVERETT SELF STORAGE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
230
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. • ,• <br /> _r_ �� <br /> Plan Check No. B 59621 � <br /> September 4, 1998 <br /> Page 3 of 5 <br /> F.ziting <br /> 1. Per the 1997 UBC, the term Corridor is specific to a fire-rated hallway exiting component. <br /> To avoid confusion, the term Hallway should be used for the exiting components used in this I <br /> building. Section 10043. <br /> 2. A door schedule should be provided so that exit widths may be reviewed. <br /> 3. It should be clarified that the stair guardrail will continue for upper-level set of stairs. Refer <br /> to Detail 7/A6.1 <br /> 4. All wall and floor/ceiling assemblies comprising the stair enclosures are required to be a <br /> minimum l Yx hour rated per Item 3 to Section 10053.3.2. Details should be provided. <br /> 5. The exit enclosure walls in both stair sections shown on Sheet A/4.3 bear on floodceiling <br /> assemblies. Those floor/ceiling assemblies and any structure supporting those assemblies are <br /> required to be rated for two-hour construction. Details should be provided <br /> 6. If the ceiling forms a protective membrane for the fire-resistive floor/ceiling assembly <br /> supporting the stair enclosures, individual protection for the struch:ral members equivalent to <br /> two-hours fire resistance will be required. Section 704.2.6 <br /> 7. The doors into the stair enclosures should 'ue shovm as 90-minute rated assemblies with <br /> maximum temperature rise not to exceed 450 degrees. Section 100533.5 <br /> 8. An approved bamer shoald be provided at the exterior exit level in thc eastern stair enclosure <br /> to prevent accidentu! exiting into the basement. Section 100533.4 <br /> 9. Exit signs should be shown at the exterior doors within the exit enclosures at the main level. <br /> Section 1003.2.8.2 <br /> 10. Stainvay identification signs conforming to the requirements of Section 1003.3.13 should be <br /> provided at each level within both stairs. <br /> 11. A means for emergency entry by the fire department into the stair enclosures should be <br /> provided per the requirements of the UFC. Section 1003.3.3.9 <br /> 12. Landings with a depth of at least 44 inches should be shown at the exterior stair enclusure <br /> doors. Section 10033.1.7 <br /> 13. The erit lighting should be shown to be provided with an emergency back-up system in <br /> accordance with the Electricai Code. Section 1003.2.9.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.