Laserfiche WebLink
' Ltt J. Degen � � <br /> February 14, 2005 <br /> Page 2 <br /> c) The plans show 5/8" suspendc.d GCB for the a:ilin�;s — the ceilings require a <br /> proprietary GWB that should be shown on the plans. <br /> 2') The columns supporting the poR cochere should be provided with mi��imum one-hour <br /> fire-resistive protection. The protection should include the connection to the beams or <br /> girders above (within the roof/ceiling assembly). A listing shouid be pmvided. Section <br /> 714.2.4 <br /> 4) See#2 abuve. <br /> 7) ii) Door#75 should swing in the opposite direction as shown. Section 100�.1.2 <br /> 7) iv) The maximum occupant load of 89 persons should be shown on the plans for the pool <br /> room. Section 1004.3 <br /> 8) i) & ii) The plans should note that the signage package is a deferred submittal. Section <br /> 106.3.4.2 <br /> Please prepare a response letter showing where each item in this comection letter is addressed <br /> on the plan set. <br /> Upon resubmission of the drawings, your application will be given priority and plan review <br /> will recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to <br /> ensure that the proposed structure�vill be consriucted in compliance with all adopt�codes. <br /> Sincerely, <br /> �1�-- <br /> Tony R. Lee <br /> Plans Examiner <br /> �/ <br />