My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3105 PINE ST HOLIDAY INN 2018-01-01 MF Import
>
Address Records
>
PINE ST
>
3105
>
HOLIDAY INN
>
3105 PINE ST HOLIDAY INN 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2018 11:35:19 AM
Creation date
12/20/2018 11:30:40 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
3105
Tenant Name
HOLIDAY INN
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
252
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` ' ' ( ( <br /> 7) 1'he poolroom has an occupant load of over 50 persons but has only one exit. The proposed <br /> weight room is sh�wn to exit through the pool area: <br /> i) A second c oinplying means of egress should be provided. Section 1014.1 <br /> ii) All egres:; doors (new or existingj should swing in the direction of travel. IBC <br /> 9ection I U08.1.2 and IFC Sections 1008.1.2 & 1026.1 <br /> iii) Doors that serve an occupant load of 100 or more should be provided with panic <br /> hardware. Section 1008.1.9 <br /> iv) The maximum occupant load should be posted. Section ]004.3 <br /> 8) The follo�ving comments refer to Meeting Room VI: <br /> i) The locations of the exit sig�s (illuminated and tactile) should be shown on the plars. <br /> Section 1011 <br /> ii) The maximum occupant load should be posted. The si�s location and nomenclat�re <br /> should be shown on the plans. Section ]004.3 <br /> 9) Cut sheets should be provided for the new horizontal sliding doors that show compliance <br /> witli the listed acceptance criteria provided in Section 1008.1.3.3. Section 1008.1.2 <br /> ]0)The following comments apply to the transfer shower stalls in the pool area restrooms: <br /> i) A minimum 48" clear floor space should be provided paralitl to the stalls. The <br /> measurement begins at the control wall and continues 12" past the seat-wall. ANSI <br /> Section 608.2.1 <br /> ii) The stalls should be shown to have interior finished dimensions of 36" x 36". ANSI <br /> Section 608.2.1 <br /> iii) The control wall should be opposite the seat-wall. Control locations should be <br /> detailed in accordance with ANSI Section 608.5. <br /> 11)Dimensions should be shown for the stall layout of the conference�enter restrooms. <br /> 12)Door 49 should have a minimum of I S" clear on the latch side from the pull direction. ANSI <br /> Section 404.2 <br /> Please prepare a response letter showing where each item in this correction letter is addressed on <br /> the plan set. <br /> Upon resubmission of the drawii�.;s, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals must be of su�cient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> / ,' ti <br /> /�/ <br /> Taay R. Lee <br /> Plans Examiner <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.