` ' ' ( ( <br /> 7) 1'he poolroom has an occupant load of over 50 persons but has only one exit. The proposed <br /> weight room is sh�wn to exit through the pool area: <br /> i) A second c oinplying means of egress should be provided. Section 1014.1 <br /> ii) All egres:; doors (new or existingj should swing in the direction of travel. IBC <br /> 9ection I U08.1.2 and IFC Sections 1008.1.2 & 1026.1 <br /> iii) Doors that serve an occupant load of 100 or more should be provided with panic <br /> hardware. Section 1008.1.9 <br /> iv) The maximum occupant load should be posted. Section ]004.3 <br /> 8) The follo�ving comments refer to Meeting Room VI: <br /> i) The locations of the exit sig�s (illuminated and tactile) should be shown on the plars. <br /> Section 1011 <br /> ii) The maximum occupant load should be posted. The si�s location and nomenclat�re <br /> should be shown on the plans. Section ]004.3 <br /> 9) Cut sheets should be provided for the new horizontal sliding doors that show compliance <br /> witli the listed acceptance criteria provided in Section 1008.1.3.3. Section 1008.1.2 <br /> ]0)The following comments apply to the transfer shower stalls in the pool area restrooms: <br /> i) A minimum 48" clear floor space should be provided paralitl to the stalls. The <br /> measurement begins at the control wall and continues 12" past the seat-wall. ANSI <br /> Section 608.2.1 <br /> ii) The stalls should be shown to have interior finished dimensions of 36" x 36". ANSI <br /> Section 608.2.1 <br /> iii) The control wall should be opposite the seat-wall. Control locations should be <br /> detailed in accordance with ANSI Section 608.5. <br /> 11)Dimensions should be shown for the stall layout of the conference�enter restrooms. <br /> 12)Door 49 should have a minimum of I S" clear on the latch side from the pull direction. ANSI <br /> Section 404.2 <br /> Please prepare a response letter showing where each item in this correction letter is addressed on <br /> the plan set. <br /> Upon resubmission of the drawii�.;s, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals must be of su�cient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> / ,' ti <br /> /�/ <br /> Taay R. Lee <br /> Plans Examiner <br /> � <br />