yt • <br /> PUBLIC WORKS <br /> 2. The comments below are General Comments. If you have any questions regarding these <br /> comments,please contact Sabrina Fandler(425-257-7813 or SFandler@everettwa.gov). <br /> a. Please see all redlines on the attached plans for required corrections in addition to all <br /> comments listed below. Frequently, redlines will be stand-alone and will not have an <br /> associated item in this corrections letter. Likewise, comments below may not have <br /> associated redlines. <br /> b. In general, please add sheet titles to each individual sheet. Suggested location would be <br /> under the sheet number, but you can place it anywhere in the title block or lower right- <br /> hand corner of the drawings, wherever makes the most sense for your drawings. <br /> c. Please see revisions to Wet Weather Grading and SWPPP Notes on sheet C-03, and <br /> apply revisions to all other sheets that this note series appears on. <br /> d. Please see redlines/revisions on sheet C-04 for your SWPPP elements evaluation. In <br /> general, please list the BMP number and name that has been selected to address each <br /> element. <br /> e. The City's `Design and Construction Standards and Specification for Development' <br /> manual were updated at the beginning of the year. This revision significantly changed <br /> the naming and numbering of several standard drawings. Please see the redlines <br /> provided on sheet C-06 for corrections, apply them to all plan sheets and callouts <br /> throughout the drawing set, and check that other references are updated to current <br /> standards. <br /> f. Please update the currently shown 15' water easement to the City of Everett to include <br /> the easement around the back side of the meter(s) and around the fire hydrants. The <br /> easement shall be 5' on one side of the main and 10' on the other (as currently shown). <br /> The portion of the easement around the hydrant shall extend 5' beyond the hydrant. The <br /> width of the easement around the meters and the fire hydrants shall be 15', on center. If <br /> other utilities encroach into this easement, it is acceptable. The easement will only be for <br /> maintenance on the water lines. <br /> g. Please see redlines on sheet C-11 for water line design revisions. A gate valve should be <br /> added to each fire hydrant, 45 degree bends with MegaLugs or equal shall be used <br /> instead of 90 degree bends, wherever possible, update construction note 5 as redlined, <br /> and update the Everett Water Notes as redlined. <br /> h. On sheet C-12, please add an 8" cleanout on the City's side of the fence (right-of-way) <br /> for the City to be able to maintain the side sewer from the right-of-way line to the main. <br /> Page 2 of 9�t' <br />