2520 MADISON ST SPRINT ANTENNA 2019-03-28
>
Address Records
>
MADISON ST
>
2520
>
SPRINT ANTENNA
>
2520 MADISON ST SPRINT ANTENNA 2019-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2019 9:11:43 AM
Creation date
3/28/2019 9:11:40 AM
Metadata
Fields
Template:
Address Document
Street Name
MADISON ST
Street Number
2520
Tenant Name
SPRINT ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTE: LEGEND — PLANS PREPARED FOR <br /> GROUND WIRES ARE SHOWN — <br /> SCHEMATICALLY. CONTRACTOR GROUND ROD ® O #2 AWGPER GROUND INSULATED <br /> LATYP. PER SECTOR <br /> SHALLEGGROUND WIRES IN TEST WELL �: Spnnt <br /> A NEAT ORGANIZED AND <br /> NON-OBSTRUCTIVE MANNER #6 AWG STRANDED INSULATED SI <br /> SEE SITE PLAN FOR EXACT COPPER GROUND BAR O COPPER GROUND WIRE z <br /> EQUIPMENT LAYOUT INTERNAL GROUND BAR O = i <br /> O #2 SOLID TINNED, BARE _ mS PROJECT MANAGER <br /> COPPER GROUND WIRE o rc <br /> EXOTHERMIC CONNECTION • 1/2" FLEXIBLE SEALTIGHT rn e <br /> IUCON <br /> MECHANICAL CONNECTION • ® SENT AT'EACH END t <br /> 41r_ L —'---'—"—" II 10590 WEST OCEAN AIR DRIVE <br /> ALL GROUND WIRES SHALL BE INSTALLED IN A NEAT ORDERLY MANNER - — SUITE 300 <br /> PIPE ANTEN(ANTENNA � © SAN DIEGO, CA 92130 <br /> r - ' i' PLANS PREPARED BY: <br /> m.m n <br /> ;� - - - V SECTOR GROUND <br /> - ©� p �I, = BAR (TYP.) FULLERTONENGINEERING <br /> .\ ©O GROUND KIT (Tl'P.) <br /> 1 I <br /> ' UPPER TOWER <br /> GPS ANTENNA SHARED HYBRID CABLE GN <br /> GROUND BAR 1100 E.WOODFIELD ROAD,SUITE 500 <br /> I = MR) SCHAUMBURG,ILLINOIS 60173 <br /> I .., I FIXING PIPE TEL•847-908-8400 <br /> q. IJ� F`�� GROUND KIT (TYP.) r�TO OTHER SECTORS CDA#3151 <br /> • www.Fullert AR 31neering com <br /> CONCRETE \ ' -- ©O III <br /> TELCQ © —ENGINEERING LICENSE&SEAL: <br /> PAD/ WORK LIGHT POST HYBRID CABLE(S) �� -- �� I HEREBY CERTIFY THAT THESE DRAWINGS WERE <br /> I f Q:>� /� I , PREPARED BY ME OR UNDER MY DIRECT <br /> WORK LIGHT ON i y ORK LIGHT <br /> �IL�d i SUPERVISION AND CONTROL, AND TO THE BEST� �� OF MY KNOWLEDGE AND BELIEF COMPLY WITH <br /> STEEL POST I PPC AND TELCO CABINET 111 . n.n.m.r-no LOWER GROUND THE REQUIREMENTS OF ALL APPLICABLE CODES. <br /> • • • •• ROUND - BAR ') C <br /> ROD1MM ��, BEI[� <br /> I • SPRINT CABINET I SPRINT �, C+F..-. 9 <br /> I I CABINET IY ''. �G> 'o <br /> • • a • ;�� % o. q <br /> / I ,' I I r <br /> �� 18" (MIN) 111 j;>� <br /> Y \ 24 MAX <br /> I ` © I I I 1: 41611 / x. <br /> 10,s� EY:I51V-1' f <br /> 1 O I — _ " <br /> SSjONA1 E146 <br /> 0 I <br /> I I © ' BELOW GRADE DRAWING NOTICE: <br /> I I GROUND RING THESE DOCUMENTS ARE CONFIDENTIAL AND ARE <br /> © / i i / THE SOLE PROPERTY OF SPRINT AND MAY NOT BE <br /> REPRODUCED,DISSEMINATED OR REDISTRIBUTED <br /> — — I — _i_1_ _ _ _ 4_ _ _ _ f f WITHOUT THE EXPRESS WRITTEN CONSENT OF <br /> ) GROUND SPRINT. <br /> © ROD (TYP.) REVISIONS:ROD "1- \ GROUND ROD DESCRIPTION DATE BY REV <br /> WITH TEST WELL GGRADE WITH TEST WELL <br /> GRROUOU ND RING <br /> REV 0 7/10/18 MH 0 <br /> GROUNDING SITE PLAN SCALE: N.T.S. 1 SINGLE LINE DIAGRAM SCALE: N.T.S. 2 REV B 6/28/18 MH B <br /> REV A 5/11/18 PD A <br /> WITH REMOVABLE SCST REW GROUND LUG HEAT SHRINK GENERAL GROUNDING NOTES: <br /> (CLEAR) SITE CASCADE ID: <br /> TYPE COVER INSTALLED NUT (EYP,) 1. GROUND RODS WILL BE 5/8" X 10 FT COPPER CLAD NOT <br /> FLUSH WITH FINISH GRADE / GROUND WIRE LESS THAN 10 FT OR MORE THAN 15 FT APART. SE52XC205 <br /> NEW GRAVEL T/GRADE T/GRADE STAR WASHER <br /> • 2. ALL CONNECTIONS TO THE GROUND RING, AND PERIPHERAL <br /> ^• ra•4' 'm'r'v'.'� '�'�'7'r'�' EQUIPMENT WILL BE MADE VIA EXOTHERMIC PROCESS UNLESS <br /> �y� f�1a € Jifi i�w�Y� Ffc' it,�gr GROUND = _—,i—II <br /> NEW WEED r.!rt�n t. i a K`f-`•I 1`00 0 I_0 `f`0.0e. M� ` OTHERWISE SPECIFIED. sITE NAME: <br /> CONTROL FABRIC w 0 �. >- <br /> �j\22 Z a \// �\� / / / BOLT (EYP.) .;, ;;, ' 3. ALL <br /> BELOW GRADE GROUND WIRES SHALL <br /> OTHERWISE SPECIFIED. BE SOLID BARE <br /> SUITABLE BACKFILL ���� z z /t/\ \�\/� ♦ 4. ALL METALLIC COMPONENTS ON THE SITE MUST BE GROUNDED PORT GARDNER <br /> COMPACTED AS REQUIRED %\\ E `�/\/ // TWO HOLE LONG BARREL •`' TO THE GROUND RING. THIS INCLUDES STEEL CONDUITS USED <br /> TO PREVENT SETTLEMENT \�\ N z SOLID TINNED '// \%� TINNED SOUR COPPER LUG • .j TOIEDELIVER THE TELCO AND POWER UTILITY LINES TO THE SITE ADDRESS: <br /> #2 AWG SOLID \ BARE COPPER \\ 5. THE CONTRACTOR MUST VERIFY THAT NEW GROUNDING SYSTEM 2599 MADISON ST. <br /> TINNED BARE >/1 / GROUND WIRE >4 <br /> i / ;o I ANTI-OXIDATION COMPOUND AT RESISTANCE IS EQUAL TO OR LESS THAN FIVE (5) OHMS. EVERETT,WA 98203 <br /> COPPER GROUND f \\ ,,,0• \,, \; <br />