My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1901 W MUKILTEO BLVD Geotech Report 2022-10-25
>
Address Records
>
W MUKILTEO BLVD
>
1901
>
Geotech Report
>
1901 W MUKILTEO BLVD Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 11:22:43 AM
Creation date
6/5/2019 8:33:08 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
1901
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Scriven Residence Improvements-REVISED NGA File No 974316 <br /> 1901 West Mukilteo Boulevard November 29,2016 <br /> Everett,Washington Page 12 <br /> We recommend that the piles be driven into place using a hydraulic hammer, with a minimum energy <br /> rating of at least 1,500 ft-lb. The piles should be spaced at a maximum distance of 4 feet, and should be <br /> embedded a minimum of 20 feet into the competent slope material below the fill. In addition to the <br /> minimum recommended embedment into the native material, the piles should be driven to a refusal <br /> criteria of less than one inch of movement during 15 seconds of continuous driving. Our explorations <br /> encountered loose undocumented fills within the planned retaining wall area. If large particles or debris <br /> are present within the fill, there is a possibility that this material may obstruct some piles at shallow <br /> depths. There should be contingencies in the budget and design for additional/relocated piles to replace <br /> piles that may be obstructed by debris in the fill. The wall lagging should be embedded a minimum of <br /> 12 inches into the finished slope face within the competent glacial soils. Any backfill placed behind the <br /> wall should consist of clean 2-inch crushed rock. The crushed rock should be tamped in place using hand <br /> tools to ensure all gaps are entirely filled. We should be retained to review final plans, observe test pile <br /> installation prior to finalizing design,monitor installation of the piles, and evaluate pile refusal. <br /> Tie-backs <br /> General: These systems should consist of drilled, grouted tieback anchors, or mechanically installed <br /> anchors such as,helical anchors. We recommend that five percent of the anchors, but no less than two <br /> anchors, be treated as performance anchors and be tested to a minimum of 200 percent of the design <br /> loads. The soil creep characteristics would be evaluated during these tests. We recommend that the <br /> foundation embedment of the residence and utilities within the yard area be verified by the contractor and <br /> measurements made in the field at the time of tieback installation to ensure tiebacks do not encounter the <br /> existing residence, or underground utilities. <br /> No-Load Zone: The anchor portion of all tiebacks must be located a sufficient distance behind the wall <br /> face to develop resistance within a stable soil mass. We recommend the anchorage be obtained behind an <br /> - assumed no-load zone. The no-load zone is defined by a line extending horizontally from the base of the <br /> wall back towards the residence a distance of four feet. The line should then extend up from the base <br /> elevation at an angle from the horizontal of 60 degrees. We expect that some undocumented fill may <br /> exist beyond the no-load zone. We therefore recommend that the bonded portion of the tiebacks, or the <br /> helical anchor helicies,be placed a minimum of 15 feet beyond the face of the wall. We recommend that <br /> we monitor soil conditions during anchor installation in order to evaluate adequate penetration into <br /> competent soils. <br /> NELSON GEOTECHNICAL ASSOCIATES, INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.