My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2212 PINE ST 2019-06-11
>
Address Records
>
PINE ST
>
2212
>
2212 PINE ST 2019-06-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 10:37:17 AM
Creation date
6/11/2019 10:37:06 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
2212
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IHB Architect <br /> Architecture "Planning *Feasibility*Project Management !mad H. Bahbah, Principal <br /> 7. Provide landings at all exterior entrance and exits and at the top and <br /> bottom of all stairs. Show on plans. <br /> Response: Landings shown on plans. See A2.1 &A5.1 for stair details. <br /> 8. Provide a retaining wall design prepared by a licensed WA State <br /> Structural Engineer for the foundation supporting the existing building <br /> adjacent to the proposed additions. <br /> Response: The retaining wall condition no longer exists, we have new <br /> plans and they are all engineered as provided in plans. <br /> 9. Table R602.3(5) IRC requires 2x6 at 16 inches on center when <br /> supporting two floors, plus a roof-ceiling assembly or a habitable <br /> attic assembly. Plans show 2x4 with no spacing specified. <br /> Response: See S-sheets tor upuated `ioor ana roof framing callouts. <br /> 10. Provide R-10 rigid insulation at all headers in walls per Table R402.1.1 of the WSEC. <br /> Response: ADDED NOTE TO ROOF FRAMING PLANS TO REFERENCE DET. B/A7.0. <br /> 11. Provide ledger details and section. Ledger bolts shall be staggered top and bottom. <br /> Response: See deta, sheet <br /> 12.Specify Lateral connection of deck per section R507.2.4 IRC. <br /> Show connection on section and in plan view. <br /> Response: See sheets S1.1, 2/A4.0, 2/A5.0 & <br /> 13. Specify post/footing connection at all new decks capable of <br /> resisting uplift and lateral displacement. <br /> Response: See Detail 11/A7.0 <br /> 14. Provide revised site plan showing 14'x 20' addition as new <br /> construction, show correct impervious surface area calculations, <br /> and show height calculations per city of Everett Residential <br /> Submittal Checklist (available on the City of Everett web site at <br /> httos://everettwa.gov/DocumentCenter/Home/view/117 ). <br /> Response: See sheets A2:i. A2.2, SS & S2.0 <br /> 15. Specify tempered safety glass in hazardous locations as defined by <br /> section R308 IRC. Show on plans. <br /> Response: See A2.1 for window size and Safety Glass (SG). <br /> 16. Differentiate new construction from existing construction on the floor <br /> plans using some kind of hatching pattern for new construction. <br /> .g 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.