Laserfiche WebLink
3. After installation, the lid/cover shall be kept bolted down during periods when work is not actively in <br /> progress at the junction box, cable vault or pull box. <br /> 4. Before closing the lid/cover, the lid/cover and the frame/ring shall be thoroughly brushed and cleaned of <br /> all debris.There shall be absolutely no visible dirt, sand or other foreign matter between the bearing surfaces. <br /> 5. When the lid/cover is closed for the final time, a liberal coating of anti-seize compound shall be applied to <br /> the bolts and nuts and the lid shall be securely tightened. <br /> 6. Hinges on the Type 4, 5 and 6 junction boxes shall be located on the side of the box,which is nearest to the <br /> adjacent shoulder. Hinges shall allow the lid to open 180 degrees. <br /> Junction box lids shall have grounding lugs and be mechanically and electrically bonded. <br /> Section 8-20.3(8) Wiring <br /> Section 8-20.3(8)is revised as follows: <br /> 8-20.3(8) Wiring (PART A) These Special Provisions are based on Snohomish County requirements and <br /> apply to all work completed within the City of Bothell and the City of Everett, for the following bid items: <br /> "SR 527 at 208th Street SE (SR 524) Temporary Traffic Signal System, Complete." <br /> "SR 527 at 208th Street SE (SR 524) Traffic Signal Modifications, Complete." <br /> "Airport Road at SR 99 (Evergreen Way) Traffic Signal Modifications, Complete." <br /> "Airport Road at 112t Street SW Traffic Signal Modifications, Complete." <br /> "Airport Road at Kasch Park Road Traffic Signal Modifications, Complete." <br /> "Airport Road BAT Lane Illumination System, Complete" <br /> The third paragraph is deleted and replaced with the following: <br /> All splices in underground illumination circuits and inductive loop circuits shall be installed in junction <br /> boxes. The only splice allowed in vehicle detection circuits shall be the splice connecting the detector lead-in <br /> conductors to the shielded home run cable. Splices for induction loop circuits shall be heat shrink type with <br /> moisture blocking material, sized for conductors. All connections with #10 and smaller wire shall use <br /> compression butt joint copper crimped connectors installed with a positive-action (ratchet) tool, except for <br /> quick disconnects as described in Section 9-29.7. The non-insulated die shall be an indent type and the <br /> insulated die shall be of a smooth shape capable of crimping pre-insulated terminals and connectors. The <br /> tool shall be a compound-lever type with a ratchet mechanism to ensure positive closure for the full <br /> crimping cycle. The tool shall be field adjustable to proper calibration with common tools and materials. <br /> Each individual conductor shall then have an approved waterproof heat-shrink tube installed, which <br /> completely covers the compression connector and extends a minimum of one-half inch beyond each end of <br /> the compression connector. All conductor connections shall be offset from adjacent connections by a <br /> minimum of one inch. A final approved waterproof heat shrink tube shall then be installed over the pair of <br /> splices in each circuit. <br /> 15 <br /> Swift II BRT Boeing to Canyon Park Station—Traffic Signal 90%Special Provisions—12/1/2016 <br />