My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11831 AIRPORT RD WHOLE SITE FILE 2020-01-21
>
Address Records
>
AIRPORT RD
>
11831
>
WHOLE SITE FILE
>
11831 AIRPORT RD WHOLE SITE FILE 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 11:19:57 AM
Creation date
6/18/2019 1:36:16 PM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
11831
Tenant Name
WHOLE SITE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
534
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Item 6 is supplemented as follows: <br /> Loop installation shall not take place in temperatures below 40°F. <br /> Item 7 is supplemented as follows: <br /> The sawcuts shall be of uniform depth and any sharp edges, abrasions, or ridges shall be removed prior to <br /> placing the wire. <br /> Sawcut Cleaning <br /> The high pressure washer shall operate at 1000 psi minimum pressure as certified by the manufacturer's <br /> label on the machine or as measured by an in line pressure gauge. <br /> All requirements of Section 1-07.15, "Temporary Water Pollution/Erosion 34 Control" shall be observed as <br /> specified in the Contract and in the Plans when the sawcut cleaning is performed. <br /> Item 11 is supplemented as follows: <br /> Loop detector sealant shall conform to one of the following specifications, chosen based on Case A or Case <br /> B application: <br /> Case A <br /> Induction Loop Detectors installed and sealed into the finish lift of asphalt shall conform to these criteria: <br /> TEST PARAMETER SPECIFICATION LIMITS <br /> Safe Heating Temperature 410° F <br /> Pour Temperature 38° F <br /> Penetration, 77° F, 6 oz, 5 sec. 10-25 dmm <br /> Penetration, 126 degrees F, 2 oz, 5 sec. 50 dmm max. <br /> Softening Point degrees F 410°F min <br /> Ductility, 125°F,in. 6°F min. <br /> Mandrel Bend, 0°F, 90°, <br /> 10 sec., 1/2 " diameter <br /> Pass 2of 3 <br /> Case B <br /> Induction Loop Detectors installed and sealed into the pavement surface prior to finish lift of asphalt (or <br /> into a paving course which is to be resurfaced within one year) shall conform to this criteria: <br /> TEST PARAMETER SPECIFICATION LIMITS <br /> Safe Heating Temperature 421°F <br /> Pour Temperature 390°F max. <br /> 21 <br /> Swift II BRT Boeing to Canyon Park Station—Traffic Signal 90%Special Provisions—12/1/2016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.