My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11831 AIRPORT RD WHOLE SITE FILE 2020-01-21
>
Address Records
>
AIRPORT RD
>
11831
>
WHOLE SITE FILE
>
11831 AIRPORT RD WHOLE SITE FILE 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 11:19:57 AM
Creation date
6/18/2019 1:36:16 PM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
11831
Tenant Name
WHOLE SITE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
534
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The shoring and boring pit plan shall be prepared by and bear the seal and signature of a <br /> Washington State licensed Professional Civil Engineer. <br /> Installed casing pipe shall be free from grease, dirt, rust, moisture and any other deleterious <br /> contaminants. <br /> Commercial concrete meeting the requirements of Section 6-02.3(2)B may be used to seal the <br /> casing. <br /> 8-20.3(6) Junction Boxes, Cable Vaults, and Pull boxes <br /> Section 8-20.3(6) is supplemented with the following: <br /> Unless otherwise noted in the Plans or approved by the Engineer, junction boxes, cable vaults <br /> and pull boxes shall not be placed within the traveled way or paved shoulders. <br /> All junction boxes, cable vaults, and pull boxes placed within the traveled way or paved <br /> shoulders shall be heavy-duty. <br /> Wiring shall not be pulled into any conduit until all associated junction boxes have been <br /> adjusted to, or installed in, their final grade and location, unless installation is necessary to <br /> maintain system operation. If wire is installed for this reason, sufficient slack shall be left to allow <br /> for future adjustment. <br /> Prior to installing new cables or reinstalling existing cables into new or existing cable vaults, pull <br /> boxes or junction boxes, the cable vault, pull box or junction box shall be cleaned of all dirt and <br /> debris. <br /> When junction boxes, cable vaults and pull boxes are installed or adjusted prior to construction <br /> of finished grade, pre-molded joint filler for expansion joints may be placed around the junction <br /> boxes, cable vaults and pull boxes. The joint filler shall be removed prior to adjustment to <br /> finished grade. <br /> When junction boxes, cable vaults or pull boxes are adjusted to finished grade, the six-inch <br /> gravel pad requirements shall be maintained. When existing junction boxes pull boxes or cable <br /> vaults do not have this gravel pad, or the gravel pad does not meet these specifications, a <br /> gravel pad, meeting these specifications shall be installed as part of the adjustment to finished <br /> grade. <br /> If junction boxes are placed in the sidewalk, they shall not be placed closer than 12 inches from <br /> the edge of any sidewalk or sidewalk joint. The frame and lid shall be from 0 to 3/16 inch below <br /> a straight edge laid across the sidewalk, and the lid shall be flat to a maximum of 1/16 inch <br /> positive camber. Premolded joint filler for expansion joints shall be placed around junction boxes <br /> installed in sidewalks. <br /> Heavy-duty Type 4, 5 and 6 junction boxes, cable vaults and pull boxes shall be installed in <br /> accordance with the following: <br /> 1. Excavation shall be sufficient to leave one foot in the clear between their outer <br /> surface and the earth bank. <br /> Swift Green Line—Corridor Stations Special Provisions SP124 <br /> May 2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.