3. Cable specifications (to the extent known, or currently labeled) <br /> 4. As-Built Records (In accordance with the Special Provisions) <br /> 5. Power Meter test results <br /> 6. Copy of the manufacturer and model number of the test equipment along <br /> with certification that the power meter has been calibrated within 12 <br /> months of the proposed test dates (previously submitted to the <br /> Engineer). <br /> 8-20.3(13) Illumination Systems <br /> Delete the 7th and 8th paragraphs of Section 8-10.3(13) and replace with the following: <br /> All new Snohomish County light standards shall have an approved metal tag riveted to the pole <br /> within 6" above the handhole on the pole shaft. Text shall be a minimum of 3/16" high, stamped <br /> or embossed. The information provided on the tag shall be as noted on the approved shop <br /> drawings, and will include the following: <br /> STD. No. XX—(Per the Plans) <br /> INTERSECTION —(AIRPORT ROAD & SR 99) <br /> MANUFACTURER <br /> APPROVED DWG XXXXXX—(Approved Drawing No.) <br /> Fab. XX/XX/)(XXX— Fabrication Date <br /> 8-20.3(13)C Luminaires <br /> Section 8-20.3(13)C is supplemented with the following: <br /> Relocate Existing Luminaire- Cobra Heads <br /> Construct foundation for relocated steel light standard with slip base for a Type A foundation per <br /> WSDOT Standard Plan J-28.30-03. Potholing is required prior to excavation if any utilities are <br /> within 10 feet. Contractor shall verify existing bolt pattern and make modifications as necessary <br /> prior to concrete installation. Verify existing lighting circuits, and break existing splices at the <br /> junction box. Remove and relocate existing luminaire to new foundation. Install new junction <br /> box, remove and replace affected lighting circuit wiring and conduit in kind. Reroute conduits <br /> and wiring, and resplice conductors at the new junction box. Remove the existing foundation, <br /> junction box, conduit bends, elbows, and obsolete conduit completely. <br /> Relocate Pedestrian Scale Lighting & Private Parking Lot Lighting <br /> Contractor shall determine existing anchor bolt type, size, and pattern; existing foundation size <br /> and depth; luminaire type, fixture type, wattage, operating voltage, and mounting height. Provide <br /> this information along with the proposed foundation design and materials for approval prior to <br /> commencing luminaire relocation work. For available Geotechnical information, see Appendix <br /> E. Construct approved foundation in proposed new location. Potholing is required prior to <br /> excavation if any utilities are within 10 feet. Verify existing lighting circuits. Remove and <br /> relocate existing luminaire to new foundation. Remove and replace affected lighting circuit <br /> wiring, conduits and handholes in kind to completely restore the lighting circuit. Remove the <br /> existing foundation,junction box, conduit bends, elbows, and obsolete conduit completely. <br /> 8-20.3(14) Signal Systems <br /> Section 8-20.3(14) is revised as follows: <br /> 8-20.3(14) Signal Systems (PART A) These Special Provisions are based on <br /> Snohomish County requirements and apply to all work completed within the City of <br /> Swift Green Line—Corridor Stations Special Provisions SP132 <br /> May 2017 <br />