My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11831 AIRPORT RD WHOLE SITE FILE 2020-01-21
>
Address Records
>
AIRPORT RD
>
11831
>
WHOLE SITE FILE
>
11831 AIRPORT RD WHOLE SITE FILE 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 11:19:57 AM
Creation date
6/18/2019 1:36:16 PM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
11831
Tenant Name
WHOLE SITE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
534
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST PARAMETER SPECIFICATION LIMITS <br /> Safe Heating Temperature 410° F <br /> Pour Temperature 38° F <br /> Penetration, 77° F, 6 oz, 5 sec. 10-25 dmm <br /> Penetration, 126 degrees F, 2 oz, 5 sec. 50 dmm max. <br /> Softening Point degrees F 410°F min <br /> Ductility, 125°F, in. 6°F min. <br /> Mandrel Bend, 0°F, 90°, <br /> 10 sec., 1/2 " diameter <br /> Pass 2 of 3 <br /> Case B <br /> Induction Loop Detectors installed and sealed into the pavement surface prior to finish lift <br /> of asphalt (or into a paving course which is to be resurfaced within one year) shall <br /> conform to this criteria: <br /> TEST PARAMETER SPECIFICATION LIMITS <br /> Safe Heating Temperature 421°F <br /> Pour Temperature 390°F max. <br /> Penetration, 77°F, 6 oz, 5 sec. 65 dmm <br /> Flow at 140°F (D3407) 0 <br /> Softening Point°F 210°F min. <br /> Resilience (D3407) 50% <br /> Penetration at 140°F 130% <br /> Case B shall be used unless otherwise specified on the Plans. <br /> The loop sealant shall be applied in accordance with the manufacturer's <br /> recommendations. <br /> Except as noted in the following pre-approved list of this Section, samples of each item <br /> shall be submitted to the Engineer for approval. <br /> Pre-approved list: <br /> • Crafco Loop Detector Sealant#34271 <br /> • 3M Detector Loop Sealant 5000 <br /> • DEERY Loop Sealant LW <br /> Item 12 is supplemented as follows: <br /> If the area around the conduit stub-out is greater than 2 inches in width, hot mix asphalt <br /> concrete shall be installed. <br /> Section 8-20.3(14)E is supplemented with the following: <br /> Signal standards shall be round tapered, not polygonal tapered. <br /> End 8-20.3(14) Signal Systems (PART A) <br /> Swift Green Line—Corridor Stations Special Provisions SP134 <br /> May 2017 <br />