My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1502 SE EVERETT MALL WAY FLOOR AND DECOR 2019-06-24
>
Address Records
>
SE EVERETT MALL WAY
>
1502
>
FLOOR AND DECOR
>
1502 SE EVERETT MALL WAY FLOOR AND DECOR 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 2:20:09 PM
Creation date
6/24/2019 2:19:44 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1502
Tenant Name
FLOOR AND DECOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STEWART + REINDERSMA ARCHITECTURE, PLLC. <br /> March 22, 2018 <br /> The City of Everett <br /> Re: Plan Review Comments <br /> Plan Review: 81801-024 <br /> Applicant: Stewart Reindersma/SRA Architecture <br /> Project Name: Floor and Decor <br /> Project Add: 1502 SE Everett Mall Pkwy <br /> Everett, WA 98208 <br /> Please find attached our revised plans with corrections made per the marked-up plan sets dated for <br /> March 9, 2018. We've updated the plans so that the revisions meet your intent and satisfy your concerns. <br /> I have provided a written response to each of your comments to where the changes or modifications have <br /> been made. All changes occurring within the set have been clouded and delta for easy correlation. <br /> Comments <br /> 1. The existing building is Type III 1-Hr (A) construction. Type II is not possible due to the <br /> wood GLB columns (and the roof is not completely heavy timber). It is possible that the <br /> building could comply as Type III-B construction — calculations would need to be <br /> supplied. If the building stays as Type III-A, fire-resistive details for the roof/ceilings, <br /> walls and columns should be provided (or heavy timber design). Section 602.3 <br /> Response: Revised sheet(s): Delta 1 <br /> G001 Revised to show type III-B construction. <br /> 2. The plans should show that special inspection will be provided for the storage racks that <br /> are 8 feet or greater in height. Section 1705.12.7 <br /> Response: Revised sheet(s): Delta 1 <br /> G001 Revised to show special inspection requirement. <br /> F100 Revised to show special inspection requirement. <br /> 3. Along with the deferred submissions for the sprinkler and fire alarm systems shown on <br /> the cover sheet, an additional, separate permit submission is required for the storage <br /> racks. <br /> Response: Revised sheet(s): Delta 1 <br /> G000 Revised to show separate permit submission for storage racks. <br /> // <br /> SRA-Stewart Reindersma Architecture,pllc 5450 E.High Street,Phoenix,Arizona 85054 t:(480)515-5123 f:(602)513-7193 <br />
The URL can be used to link to this page
Your browser does not support the video tag.