My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Jansen Inc 6/10/2019
>
Contracts
>
Capital Contract
>
Jansen Inc 6/10/2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2021 10:31:13 AM
Creation date
7/9/2019 11:12:22 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Jansen Inc
Approval Date
6/10/2019
Council Approval Date
5/29/2019
Department
Public Works
Department Project Manager
Ryan Sass
Subject / Project Title
Downtown Streetscape Improvement
Public Works WO Number
PW3553 PW3640 UP3648
Tracking Number
0001861
Total Compensation
$9,577,841.02
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
Jansen Inc 11/6/2019 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
Jansen Inc 12/21/2019 Change Order 2
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
Jansen Inc 3/20/2020 Change Order 3
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
Jansen Inc. 1/16/2021 Change Order 4
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract\Franchise
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
698
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> I <br /> 1 9-29.13(10)D Cabinets for Type 170E and 2070 Controllers <br /> 2 The first sentence of item number 4 is revised to read: <br /> I3 <br /> 4 A disposable paper filter element with dimensions of 12" x 16" x 1" shall be provided in lieu <br /> 5 of a metal filter. <br /> I6 <br /> 7 Item number 6 is revised to read: <br /> 8 <br /> 9 6. LED light strips shall be provided for cabinet lighting, powered from the Equipment <br /> I10 breaker on the Power Distribution Assembly. Each LED light strip shall be <br /> 11 approximately 12 inches long, have a minimum output of 320 lumens, and have a color <br /> 12 temperature of 4100K (cool white) or higher. There shall be three light strips for each <br /> I13 rack within the cabinet. Lighting shall be ceiling mounted — rack mounted lighting is not <br /> 14 permitted. Light strips shall be installed in the locations shown in the Standard Plans. <br /> 15 Lighting shall not interfere with the proper operation of any other ceiling mounted <br /> I <br /> 16 equipment. All lighting fixtures above a rack shall energize automatically when either <br /> 17 door to that respective rack is opened. Each door switch shall be labeled "Light". <br /> 18 <br /> I <br /> 19 Item number 7 is revised to read: <br /> 20 <br /> 21 7. Rack mounted equipment shall be as shown in the Standard Plans. The cabinet shall <br /> I22 use PDA#2LX and Output File #1 LX. Where an Auxiliary Output File is required, <br /> 23 Output File #2LX shall also be included. <br /> 24 <br /> 25 This section is supplemented with the following new item: <br /> I <br /> 26 <br /> 27 9. The PCB connectors for Field Terminal Blocks FT1 through FT6 on Output Files #1 LX <br /> 28 and #2LX shall be capable of accepting minimum 14 AWG field wiring, have a pitch of <br /> I29 5.08 mm, and use screw flange type locking to secure the plug and socket connection. <br /> 30 The sockets on the Field Terminal Panel shall be secured to the panel such that <br /> 31 unplugging a connector will not result in the socket moving or separating from the <br /> 111 32 panel. <br /> 111 33 <br /> 34 9-29.13(11) Cabinets for Type 170E and 2070 Controllers <br /> I <br /> 35 Item number 2 is revised to read: <br /> 36 <br /> 37 2. Rack mounted equipment shall be as shown in the Standard Plans. <br /> I38 <br /> 39 Item number 3 is revised to read: <br /> 40 <br /> 41 3. PDA#3LX shall be furnished with three Model 200 Load Switches installed. PDA #3LX <br /> I <br /> 42 shall be modified to include a second Model 430 transfer relay, mounted on the rear of <br /> 43 the PDA and wired as shown in the Standard Plans. <br /> 44 <br /> I45 9-29.13(12) ITS Cabinet <br /> 46 This section's title is revised to read: <br /> 47 <br /> I48 Type 331L ITS Cabinet <br /> 49 <br /> 50 The first paragraph (excluding the numbered list) is revised to read: <br /> City of Everett Page AM-109 Amendments <br /> Everett Downtown Streetscape Improvement March 22, 2019 <br />
The URL can be used to link to this page
Your browser does not support the video tag.