Laserfiche WebLink
Pian Check !/ B-40648 <br />June 14, 1993 <br />Page Two of Three <br />� <br />6. Stairs No. 1 and 3 must be encfosecl. Section 3309(a). <br />Enclosures must be of one hour construction with one hour rated openings. <br />The enclosures as illustrated on sheets M3. l, M3.2 & M3.3 would be acceptable. <br />7. 3/4 hour rated openings are required onto the exterior exit balcony and within 10 feet of the <br />new exterior exit stair. Section 3306(k). <br />8. The opening between the infants Room I IS and the corridor No. 197 is prohibited see item <br />6. <br />9. 1'he openings between the commons Rooin 206 and corridor No. : 92 cannot exceed 25% of <br />the area of the wall Section 3305(h)2. <br />10. The openink between the reading Room 330 and stair No. 2 is prohibited. Section 3309(c). <br />11. lJsable space under stairs (pantry 147) is prohibited. Section 3309(�. <br />12. The following doors must be one hour rated: 103A, ]03B, I 15, 116A, 117, 120. <br />13. The following doors must be 3/4 hour rated: 192, 195, 249B, 293, 205B, 207A. <br />14. Openings into corridors other than doors must be 3/4 hour rated. Secdon 3305(h)2. <br />I5. The van accessible parking stall should be tocated near the tot lot (public parldng area). <br />16. Provide directional signage from the accessible public parking ro the elevator entrance and <br />to the administrative office area. <br />17. The exterior ramps along the east side of the b�ilding must have handrails. Secdon <br />3106(h)5. <br />18. Standard height drinking fountains must also be provided. Section 3105(d). <br />19. Ensure corridors 294 and 295 are wide enough to provide maneuvering spaces per Section <br />3106(j)3. <br />20. Provide maneuvering spaces per Section 3106(j)3 at the foilowing doors. ' <br />,.I 15, 144, 145 and gates within the daycare area between diaper room 146 and tocldler room <br />144 and between the kitchen 143 and toddler room 144. <br />21. Insulation should be provideci within the heatecl attic space at the exterior walls. <br />