My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3516 RUCKER AVE SEQUOIA HIGH SCHOOL 2018-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
3516
>
SEQUOIA HIGH SCHOOL
>
3516 RUCKER AVE SEQUOIA HIGH SCHOOL 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2019 10:33:13 AM
Creation date
7/18/2019 7:20:56 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3516
Tenant Name
SEQUOIA HIGH SCHOOL
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
392
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pian Check !/ B-40648 <br />June 14, 1993 <br />Page Two of Three <br />� <br />6. Stairs No. 1 and 3 must be encfosecl. Section 3309(a). <br />Enclosures must be of one hour construction with one hour rated openings. <br />The enclosures as illustrated on sheets M3. l, M3.2 & M3.3 would be acceptable. <br />7. 3/4 hour rated openings are required onto the exterior exit balcony and within 10 feet of the <br />new exterior exit stair. Section 3306(k). <br />8. The opening between the infants Room I IS and the corridor No. 197 is prohibited see item <br />6. <br />9. 1'he openings between the commons Rooin 206 and corridor No. : 92 cannot exceed 25% of <br />the area of the wall Section 3305(h)2. <br />10. The openink between the reading Room 330 and stair No. 2 is prohibited. Section 3309(c). <br />11. lJsable space under stairs (pantry 147) is prohibited. Section 3309(�. <br />12. The following doors must be one hour rated: 103A, ]03B, I 15, 116A, 117, 120. <br />13. The following doors must be 3/4 hour rated: 192, 195, 249B, 293, 205B, 207A. <br />14. Openings into corridors other than doors must be 3/4 hour rated. Secdon 3305(h)2. <br />I5. The van accessible parking stall should be tocated near the tot lot (public parldng area). <br />16. Provide directional signage from the accessible public parking ro the elevator entrance and <br />to the administrative office area. <br />17. The exterior ramps along the east side of the b�ilding must have handrails. Secdon <br />3106(h)5. <br />18. Standard height drinking fountains must also be provided. Section 3105(d). <br />19. Ensure corridors 294 and 295 are wide enough to provide maneuvering spaces per Section <br />3106(j)3. <br />20. Provide maneuvering spaces per Section 3106(j)3 at the foilowing doors. ' <br />,.I 15, 144, 145 and gates within the daycare area between diaper room 146 and tocldler room <br />144 and between the kitchen 143 and toddler room 144. <br />21. Insulation should be provideci within the heatecl attic space at the exterior walls. <br />
The URL can be used to link to this page
Your browser does not support the video tag.